2. Safety Regulations
Attention: Check the liquid level before opening the still door.
Attention: Do not dispose of distillation residues in the sewer system
Requirements for the owner and operating personnel
According to the legal stipulations of the German accident prevention
regulations BGR 500 chapter 2.14 and the 2nd BlmSchV, special knowledge
is required for the operation and maintenance of drycleaning systems. A
person with this special knowledge must regularly be present during the
operation of drycleaning systems.
As a person / body who runs a plant one is obliged to have the refrigerating plant of
the dry cleaning machine inspected annually with regard to tightness.

2.4. Repair Work

Only skilled workers with suitable protection devices and work tools are authorized to carry out
repairs. Make sure that there are no solvent emissions.
During repair and cleaning work:
Turn main switch off
Close the stop valves on the supply lines (steam, condensate and compressed air).
Make sure that the system cannot be turned on without permission (close off and put
up a sign " DO NOT TURN ON – REPAIR WORK")
Always remove the main fuse when working on the electrical system.
Use only original fuses to replace defective ones.
When working on pneumatic control parts, make sure that there is no pressure in the system.
Only specially trained refrigeration technicians are authorized to make repairs to the refrigeration unit.
All spare parts used must comply with the technical standards set by the manufacturer.
4
The collecting tank must hold the amount that is expected to
be drained and must be temperature and solvent-resistant.
or normal garbage. You must dispose of these residues
according to country-specific regulations on special waste.