• (Fig. 20): air intake (F) on the cladding, chan-
nelled to the hearth. Lower grate (A) supplied
on the cladding and wall hole (B) for the recir-
culation of ambient air.
B
F
The image is purely indicative.
L'immagine è puramente indicativa.
The Ecomonoblocco is equipped, on the right
side, with a dedicated flange (D) with a diameter
of 110 mm, for the inlet of combustion air.
The heat recovery grate (E) supplied with the
product must be positioned on the top part of
the lining.
In the case in the room where is located the
fireplace there are one or more extraction fans
operating (suction hoods) malfunctions to the
combustion may occur caused by a shortage of
combustion air.
004778610 - 16/12/2020
ITALIANO
ENGLISH
E
D
Fig. 19
E
D
A
Fig. 20
DEUTSCH

7.8 Hot air delivery connection

Only for models V16 - V16 EPLUS
7.8.1 Hood liner fitting for heating in a single
environment
Apply the flexible pipes (Ø 140 mm) for the
distribution of hot air to the front outlet vents,
above the hood, securing them with the appro-
priate clamps. Soundproof the pipes by covering
them with insulating material (ecological insula-
tion mat) (Fig. 21 : A-clamps, B-distribution hose,
C-insulation, D-vents).
B
A
7.8.2 Channelled pipelines fitting for heating
in multiple rooms
To heat several rooms, it is possible to create
metal pipelines for air distribution according to
the following diagram:
• Flexible aluminium hose - length up to 6 m on
a single duct (Fig. 22);
• Smooth metal pipe - length up to 10 m on a sin-
gle duct (Fig. 22);
• Smooth metal pipe - length up to 14 m on dou-
ble duct (Fig. 23).