4.5 Wiring diagram

WT60 3D V16
USER INTERFACE
UI
PE
~220 - 240 Vac
NOTE:phase protection,added by customer.Do not change polarity!
Air
1
Room fan
2
Flue gas probe
004778610 - 16/12/2020
ITALIANO
ENGLISH
C01
GND
~220 - 240 Vac
L
N
O01
DEUTSCH
FRANÇAIS
3
T02
F03
F01/02 +VIO
GND
I02
O02
O03
O04
1
Air
3
Room sensor
Control panel
ESPAÑOL
2
K
T01
T03
+
-
I01