6. HOW TO COMMUNICATE WITH ID TAGS
Table 6.6 Remote Device Station Initialization Procedure Registration Settings
Procedure Execution Condition
Initial data processing request flag (RX78) ON
Initial data processing request flag (RX78) OFF
Initial data setting complete flag (RX79) ON
6 - 15
(b) Setting the procedure registration
When the initial data processing request flag (RX78) turns ON and the Remote
device station initialization procedure registration instruction (SB0D) is turned
ON, the contents below are registered in ECL2-V680D1.
Sets the communication specification to "Trigger". (Sets RWw0 to 0.)
Sets the following communication settings:
Write verify setting: Execute
ID tag communication speed setting: Standard mode
Write protect setting: Enable
Read/Write data code setting: Without ASCII/HEX conversion
(sets RWw1 to 0)
Sets the processing specification to the following data storage order:
Upper → Lower. (Sets RWw2 to 0.)
Sets the auto system command wait time setting to continual ID
command execution until there is a response from the ID tag. (Sets
RWw3 to 0.)
Turns the initial data processing complete flag (RY78) ON.
Turns the initial data setting request flag (RY79) ON.
Turns the initial data processing complete flag (RY78) OFF.
Turns the initial data setting request flag (RY79) OFF.
(c) Setting result
The setting result is shown below.
Description