Mitsubishi Electric RFID ECL2-V680D1 User Manual page 32

Interface module
Table of Contents

Advertisement

3. SPECIFICATIONS
Mode Switch Set
Value
0
RWwm+FH
1 to 3
4
RWwm+7H
5
RWwm+FH
6
RWwm+1FH
7
RWwm+3FH
8 to F
Mode Switch Set
Value
0
1 to 3
4
5
6
7
8 to F
3 - 12
*1. The last address is as follows according to the mode switch setting.
Table 3.10 Remote Register Last Address
Last Address
RWw
RWr
RWrm+FH
-
-
RWrm+7H
RWrm+FH
RWrm+1FH
RWrm+3FH
-
-
*2. The address and contents in RUN mode are as follows according to the mode
switch setting.
Table 3.11 Remote Register Address Range
Address
RWwm+3H to RWwm+FH
RWrm+3H to RWrm+FH
-
RWwm+3H to RWwm+7H
RWrm+3H to RWrm+7H
RWwm+3H to RWwm+FH
RWrm+3H to RWrm+FH
RWwm+3H to RWwm+1FH
RWrm+3H to RWrm+1FH
RWwm+3H to RWwm+3FH
RWrm+3H to RWrm+3FH
-
Ver. 1 compatible, 4 occupied stations, RWw/RWr: 16 points each
Ver. 1 compatible, 2 occupied stations, RWw/RWr: 8 points each
Ver. 2 compatible, 2 occupied stations, Expanded cyclic setting
Ver. 2 compatible, 2 occupied stations, Expanded cyclic setting
Ver. 2 compatible, 2 occupied stations, Expanded cyclic setting
m: Address assigned to master station by station number setting.
Description
Write data specification areas 1 to 13
Read data storage areas 1 to 13
-
Write data specification areas 1 to 5
Read data storage areas 1 to 5
Write data specification areas 1 to 13
Read data storage areas 1 to 13
Write data specification areas 1 to 29
Read data storage areas 1 to 29
Write data specification areas 1 to 61
Read data storage areas 1 to 61
-
m: Address assigned to master station by station number setting.
Remarks
-
: Double, RWw/RWr: 16 points each
: Quadruple, RWw/RWr: 32 points each
: Octuple, RWw/RWr: 64 points each
-
Remarks
Ver. 1 compatible, 4 occupied
stations, 13 points (26 bytes)
Ver. 1 compatible, 2 occupied
stations, 5 points (10 bytes)
Ver. 2 compatible, 2 occupied
stations, Expanded cyclic setting
: Double, 13 points (26 bytes)
Ver. 2 compatible, 2 occupied
stations, Expanded cyclic setting
: Quadruple, 29 points (58 bytes)
Ver. 2 compatible, 2 occupied
stations, Expanded cyclic setting
: Octuple, 61 points (122 bytes)
-
-
3 - 12