3. SPECIFICATIONS
Device No.
Signal Name
ID command execution
RYn4
request
TEST mode execution
RYn5
request
RYn6
Result reception
Initial data processing
RY(n+k)8
complete flag
Initial data setting
RY(n+k)9
request flag
3 - 10
(2) Remote output signals
Table 3.8 Remote Output Signal Details
(1)
Executes the ID command of the contents set in the remote register (RWw) when the
sequence program turns ON.
(2)
For the timing chart, refer to "ID command complete (RXn4)".
(1)
Executes TEST mode when turned ON by the sequence program.
This signal is used only when the communication specification is repeat auto or FIFO repeat.
(1)
Used as a trigger signal for communication with the next ID tag when the communication
specification is repeat auto or FIFO repeat.
(2)
The timing chart is as follows:
1) The result information is acquired and result reception (RYn6) is turned ON when ID
command complete (RXn4) turns ON.
2) ID command complete (RXn4) turns OFF when result reception (RYn6) is turned
ON.
3) Result reception (RYn6) is turned OFF when ID command complete (RXn4) turns
OFF.
ID command
complete
(RXn4)
Result reception
(RYn6)
(1)
Turns ON after initial data processing is completed when there is an initial data
processing request after power ON or reset.
(2)
For the timing chart, refer to "Initial data processing request flag (RX(n+k)8)".
(1)
Turns ON when initial data is set or changed.
(2)
For the timing chart, refer to "Initial data processing request flag (RX(n+k)8)".
(3)
Not executed during ID command execution, even if the initial data setting request flag
(RY(n+k)9) is turned ON. Turn the flag ON after turning the ID command execution
request (RYn4) OFF and the ID command is completed.
(4)
Not executed in TEST mode, even if the initial data setting request flag (RY(n+k)9) is
turned ON.
Description
Implemented by RFID interface module
Implemented by sequence program
1)
n: Address assigned to master station by station number setting.
k: Address assigned by set value of mode switch.
2)
3)
3 - 10