2.3.2. Series Connection:
Before wiring the battery model, make sure all batteries are turned off. Follow the steps
shown below for wiring. Then press any battery's Power button one by one.
Please Note:
1. The maximum number of series connections is limited to 2 pcs - 24V.
2. Each battery should have the same capacity and the same voltage. Otherwise it will
affect subsequent use
3. Ensure that the voltage difference between the batteries should not exceed 0.2V
before connection. If batteries do exceed 0.2V difference then all batteries will
require a full charge so they are an equal voltage.
4. Connect all batteries in parallel (considering point 3 above) for 12-24 hours so that
batteries are equalized before connecting in series
5. If one battery goes into protective mode, the whole system will shut down

Installation Environment

3.
Battery operating environment requirements are as follows:
Working temperature:
Humidity:
Altitude:
The site environment:
damaging gas, no damaging insulation Conductive dust
Master Instruments Pty Ltd
0℃ - 50℃
5% - 95%
<4000m
Away from heat, no corrosive gas, no explosive gas, no