The plug insert is available in two sizes (16 Fr. and 20 Fr.) for use with the Blom-Singer Classic and Advantage Indwelling
Voice Prostheses. Ensure that the size of the plug insert correctly matches the size of the voice prosthesis. Insert the plug
insert only while using a close-up mirror and a bright light focused directly into the stoma. The indwelling accessory device
should always be cleaned to prevent contaminants from entering into the tracheostoma, puncture, or esophagus. The
user's hands should always be washed with soap and water prior to cleaning the plug insert.
1
3
5
7
Insertion of the
Blom Singer
The plug insert is designed to prevent leakage through the
voice prosthesis until such time that the voice prosthesis
and TEP is evaluated by a clinician; it does not allow voicing.
INSERTION INSTRUCTIONS
The plug insert consists
a
of a plug tip (a) and neck
strap with safety hole.
Attach the safety hole in the
neck strap on the plug insert
securely and completely
down over the safety peg on
the inserter tool. This should
prevent inadvertent dislodg-
ment of the plug insert off the
inserter tool during insertion
into the voice prosthesis.
After confirming that the plug
insert is securely in place and
fully inserted, the inserter tool
should be carefully removed.
Apply a strip of
hypoallergenic medical
adhesive tape over the
neck strap to prevent
strap movement.
Plug Insert
®
2
4
6
* CAUTION: If the device does not insert easily on the first attempt, do not continue to try
to insert it. Should you experience repeated difficulty in managing the plug insert, contact your
physician/clinician as soon as possible.
**Caution should be exercised when removing the inserter tool to avoid accidental displacement
of the plug insert or voice prosthesis which could result in aspiration (inhalation) of the device or
voice prosthesis. Should aspiration occur, attempt to cough the device and/or voice prosthesis
out of the windpipe. Seek medical attention immediately if unsuccessful.
CAUTION: Do not use plug insert with a 4 mm size voice prosthesis. The plug insert will not
fully insert into a 4 mm size voice prosthesis due to the shorter length of the voice prosthesis
shaft. This could result in pushing the voice prosthesis into the esophagus.
WARNING: Do not detach or in any way modify the neck strap on the plug insert. The neck
strap should not, under any circumstances, be cut or removed from the plug insert. The
neck strap is intended to help prevent accidental aspiration (inhalation) of the device should the
device become dislodged. This device is designed for temporary use only (maximum of 30 days)
and is not intended to replace the indwelling voice prosthesis.
INSTRUCTIONS FOR USE: https://www.inhealth.com/v/vspfiles/pdf/IFU/R1/37582-01G.pdf
Available since 1995
Place the tip of the inserter
tool into the open end of
the plug insert.
Carefully and gently insert
the plug insert until it is fully
inserted and positioned flush
with the voice prosthesis.
Never force the plug insert
into the voice prosthesis
.
*
Hold the inserter tool and the
neck strap together firmly in
one hand. Carefully lift the
neck strap off the safety peg
on the inserter tool. Hold the
neck strap against the neck
while slowly and gently with-
drawing the inserter tool with
a twisting motion.
**

Advertisement

loading

Summary of Contents for inhealth Blom Singer

  • Page 1 (inhalation) of the device should the device become dislodged. This device is designed for temporary use only (maximum of 30 days) and is not intended to replace the indwelling voice prosthesis. INSTRUCTIONS FOR USE: https://www.inhealth.com/v/vspfiles/pdf/IFU/R1/37582-01G.pdf...
  • Page 2 InHealth Technologies 1110 Mark Avenue Carpinteria, CA 93013-2918 USA Toll-Free: 800.477.5969 Severn Healthcare Technologies Ltd. 42 Kingfisher Court, Hambridge Road Order online at www.inhealth.com Newbury, Berkshire, RG14 5SJ Email: service@severnhealthcare.com Tel: 01635 887640 ©2020 InHealth Technologies®—Manufactured by Freudenberg Medical, LLC (200406.00)