6. In the Services field, select whether you want to allow access to OTMC 100 via the web interface
(Web) or the Application Programming Interface API (SOAP) only or via both interfaces.
7. Click the Save button.
8. Your new password is applied to your OTMC 100 and a login dialog appears.
For more information, please refer to
Perform a factory reset on the device if you forgot your password (see
performed directly on the device

6.1.3 Running a software update for OTMC 100

Please note that OTMC 100 will not deliver time information during a software update.
1. Click the Tools icon in the navigation bar of the web interface.
2. Click the Software Update icon.
3. Click the Browse... button to navigate to the software image file and select it.
4. Deselect the Keep settings check box if you want to reset the device configuration to the factory
defaults after the software update. If the check box is selected, the user specific configuration
settings are kept during the software update.
5. Click the Update button to start the software update.
6. The update process may take up to ten minutes. Do not disconnect OTMC 100 or the computer
during this process.
7. OTMC 100 automatically restarts after the software update has completed.
If the software update process fails due to any reason, OTMC 100 enters a recovery mode
on the next power-up. In this mode, the device provides only a rudimentary web interface
(similar to the Software Update page) just allowing for the upload of a software image (see
Uploading new software to the device in recovery mode

6.1.4 Performing a reboot of OTMC 100

A device reboot can also be performed directly on the device (see
performed directly on the device
1. Click the Tools icon in the navigation bar of the web interface.
2. Click the Device Control icon.
3. Click the Reboot button next to Reboot device.
4. OTMC 100 performs a reboot. The device will be ready for operation again after approx. 15 s.