First Fire; Operating; Optional Blower Operation; Flame Adjustment - Pacific energy B Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

FIRST FIRE

When lit for the first time, the appliance will emit a slight odour for a
couple of hours. This is due to the curing of paints, sealants and
lubricants used in the manufacturing process. This condition is
temporary. Open doors and windows to ventilate area. Smoke and
fumes caused by the curing process may cause discomfort to some
individuals.

OPERATING

The Mirage DV comes equipped with a millivolt combination gas
valve. An optional wall thermostat may be installed to operate the
burner automatically. Once a pilot light has been established, and the
gas valve knob turned to the "ON" position, the unit may be operated
one of two ways:
Fig. # 16
Manual HI-LO Control Knob
BURNER
CONTROL
Manual HI-LO Flame Adjustment:
1) The HI-LO burner control knob can be rotated in both directions,
providing infinite control of gas flow rate to the burner and
therefore greater comfort control. The HI setting provides a
maximum gas input, and rotating the knob clockwise toward the
LO setting will reduce the gas input to a minimum setting.
Wall Thermostat (optional):
2) Set the wall thermostat to a comfortable temperature. Turn the
HI-LO burner control knob to a desired setting. As heat is
required, the Mirage DV will turn on or off automatically.
Extend Shutdown:
1) To shutdown the appliance including the pilot, partially depress
and turn gas control knob clockwise past "PILOT" to "OFF"
position. DO NOT FORCE.
NOTE: The SIT control has an interlock device which does not allow
the pilot to be lit when the appliance is at operating temperature. Let
the appliance cool down (approx. 60 sec.) before attempting to relight
the pilot. DO NOT use force to rotate the control knob.

OPTIONAL BLOWER OPERATION

The circulating air blower is thermostatically controlled and will not
operate if appliance is cold. A few minutes after the appliance is lit and
the variable speed control set at a desired setting, the blower will
automatically turn on. The blower will automatically turn off a few
minutes after the appliance is shut down.

FLAME ADJUSTMENT

The air shutter on the burner venturi tube controls the primary
combustion air to the gas burner. Some adjustment may be neces-
sary to obtain desired flame and to eliminate carbon deposits. (See
Fig. # 17 for proper flame pattern)
Fig. # 17
Caution: Firebox side may be hot!
To Adjust: (See Fig. # 18)
1) Loosen side panel retaining screws and open right side panel to
expose controls
2) Move air shutter adjustment rod in or out until proper flame is
achieved.
3) Close control side panel and tighten screws.
Fig. # 18
Caution: Proper air shutter setting is a must.
The flame should be just orange and "lazy". It should NEVER be set
to create sooting on internal parts and glass. Open air shutter
gradually until sooting stops.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

The mirage direct vent

Table of Contents