Mitsubishi Electric -MR-CV User Manual page 11

Power regeneration converter unit
Table of Contents

Advertisement

400 V class
Model MR-CV_
Output
Rated voltage
Rated current [A]
Main circuit power
Voltage/Frequency
supply input
Rated current [A]
Permissible voltage fluctuation
Permissible frequency fluctuation
Power supply capacity [kVA]
Inrush current [A]
Control circuit power
Voltage/Frequency
supply input
Rated current [A]
Permissible voltage fluctuation
Permissible frequency fluctuation
Power consumption [W]
Inrush current [A]
Interface power
Voltage
supply
Current capacity [A]
Capacity [kW]
Protective functions
Main circuit method
Continuous rating [kW]
Instantaneous maximum rating [kW]
Satisfied standards
CE marking
UL standard
Structure (IP rating)
Environment
Ambient temperature
Ambient humidity
Ambience
Altitude
Vibration resistance
Mass [kg]
*1 This value is applicable when all I/O signals are used. Reducing the number of I/O points decreases the current capacity.
*2 This does not apply to the terminal block.
*3 Refer to the following for restrictions on using this product at an altitude exceeding 1000 m and up to 2000 m.
Page 15 Restrictions when using this product at an altitude exceeding 1000 m and up to 2000 m
11K4
18K4
513 V DC to 648 V DC
21
38
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
18
35
3-phase 323 V AC to 528 V AC
Within ±3 %
Page 67 Power supply capacity and generated loss
Page 69 Inrush currents at power-on of main circuit and control circuit
1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
0.1
1-phase 323 V AC to 528 V AC
Within ±3 %
30
Page 69 Inrush currents at power-on of main circuit and control circuit
24 V DC ±10 %
*1
0.35
11
18
Undervoltage protection, regenerative error protection, regenerative overvoltage shut-off, MC
drive circuit error protection, open-phase detection, inrush current suppression circuit error
protection, main circuit device overheat error protection, cooling fan error protection, overload
shut-off (electronic thermal)
Converter with power regeneration function
7.5
11
39
60
LVD: EN 61800-5-1 EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL 508C
Force cooling, open (IP20)
Operation
0 ˚C to 55 ˚C (non-freezing)
Storage
-20 ˚C to 65 ˚C (non-freezing)
Operation
5 %RH to 90 %RH (non-condensing)
Storage
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude 2000 m or less
2
5.9 m/s
, 10 Hz to 55 Hz (in each of the X, Y, and Z directions)
6.1
30K4
37K4
45K4
72
82
99
61
70
85
30
37
45
20
25
25
92
101
125
*2
*3
12.1
1 FUNCTIONS AND CONFIGURATION
1.3 Standard specifications
1
55K4
75K4
119
150
106
130
55
75
55
55
175
180
25.0
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents