Starting The Pump; Paperwork And Iom - Xylem Goulds M05430 Instruction Manual

4" submersible pumps
Hide thumbs Also See for Goulds M05430:
Table of Contents

Advertisement

Available languages

Available languages

Current unbalance should not exceed
5%. If the unbalance cannot be cor-
rected by rolling leads, the source of
the unbalance must be located and
corrected. If, on the three possible
hookups, the leg farthest from the
average stays on the same power
lead, most of the unbalance is coming
from the power source.
Contact your local power company
to resolve the imbalance.
5.0 STARTING
5.0 STARTING
THE PUMP
THE PUMP
5.1 Install a Valve
CAUTION
and Run the Pump To
Clear the Water
On a new well - Install a
Hazardous pressure can
ball or globe valve on the
cause personal injury
or property damage.
pump discharge line and
with the valve
1
3
well until the water begins to run
clear. Open the valve slowly to check
flow and when the water runs clear
turn the pump Power Off.
Remove the ball or globe valve and
connect the pump discharge to the
house plumbing, pressure tank and
switch. Turn Power On. Run a few
cycles through the tank to rinse it
out and to verify proper pump and
switch operation. Use this time to
check all fittings for leaks.
CAUTION: If the well has a high
static level, please see next section
for important pump protection
information.
12
open, pump the
5.2 Throttling A
CAUTION
High Static
Level Well To
Prevent Upthrust
Hazardous pressure can
cause personal injury
or property damage.
Any well with a high static water
level may allow the pump to operate
off the curve to the right or outside
the "Recommended Range" shown
on the pump curve. We recommend
using a "Dole" flow restrictor or
throttling with a ball valve to prevent
upthrust damage to the pump and
motor. The maximum flow must be
restricted to be within the pumps
recommended operating range. If
you use a ball valve, set it, remove the
handle, tape the handle to the pipe,
and tag the valve with a note saying,
"Do not open this valve or pump
may be damaged". The easiest way
to "set" the flow is to fill a 5 gallon
bucket and time how long it takes to
produce 5 gallons. Calculate the flow
in gpm based on this value. As the
water level drops in the well the flow
will be reduced due to increased head
and the valve will not interfere with
performance.
6.0 PAPERWORK
6.0 PAPERWORK
and IOM
and IOM
Please give this filled-in IOM and
your business card to the owner.
A sticker with your name and phone
number on the tank or control box is
a great sales tool for future business!
We now provide an extra pump label
which you can affix to the IOM, put
on a 3-wire control box or locate
near the tank and pressure switch for
future pump identification.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents