Pan detection

Pans with a diameter of less than 12 cm (bottom) are not recognized. During operation, the
power indicator lamp, LED or digital display indicates the selected power level (1-9). When
operating without a pan or an unsuitable pan material, no power is emitted, the power indicator
lamp flashes only briefly or the indicator does not report a pot detected

Monitoring of the heating zone

The heating zone is monitored by a temperature sensor (middle of the cooker) located under the
ceramic field. Overheated pans (hot oil, empty pans) can be detected in the middle of the
cooking place. The energy supply is stopped. The device only transfers energy back to the pan
until the temperature has dropped to a normal level.
Attention! Only the cooking appliance is protected from overheating, not the pan. The
overheated pan is not detected until the overheating of the ceramic field has reached the
shutdown temperature (260°C).

Noise

The fans of the cooling are audible, but switch off again in between.

General

This manual contains basic information that must be observed during assembly, application and
maintenance. It must be read completely by the installer and the operator before installation
and commissioning, and must always be located near the cooking station for a look-up.

Application

The inductiongeräte are used for preparing meals. They can be used for cooking, keeping warm,
flaming, grilling, etc. of food. Attention, onlyinduction-grade pan material must be used on
induction gerät
en. For the use of the pan material, only products recommended by us and
suitable for professional use should be used. The entire bottom of the pan must be magnetic. In
case of doubt, this can be tested with the help of a permanent magnet.

Product

Products

Compact modular design
-
Easy operation by rotary knob
-
Compact power electronics enable easy and safe operation
-
Max operational safety thanks to various protection and monitoring functions
-
Continuous power control with electronic overtemperature protection of the
-
performance part.
At Sauteusenspulen:5-Fühler-Temperaturüberwachung für verbesserten Topfschutz.
-

Technical data

Operation and control

Lamp "Operation or pot detection"
Power Controller - Potentiometer0Ohm - 10kOhm
Digital display "Power and error display"
Lamp "Operation" green (devices with main switch)
Ver. 3.6
Page 6 Of 44
see error messages.
2V DC/approx. 10mA (LED green)
2.8V DC/approx. 60mA (red)
© Bernese cooking systems 2018
17.07.2014

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents