Overview Alerts on Display

Display Importance
Raw mode
DC
Overcurrent
Fan error
Wrong pot
HF
Overcurrent
RTC error

Overview Faults on display

Display Importance Declaration
Fault 1
Fault 2
Fault 3
Fault 4
Fault 5
Fault 6
Fault 7
Fault 8
Fault 9
Fault 10
Fault 11

Cleaning

Warning: During cleaning or maintenance and when parts replace, the equipment must
be disconnected from the power supply.
Ver. 3.6
Declaration
Development and diagnostic mode
No limits active! Display only on standby
DC current greater than 350mA (too many or wrong fans)
flashing. Display every 10 seconds for 1 second.
Fan not connected or blocked
Display appears every 10 seconds for 1 second.
Criterion: Fan level high min. 150mA or RippleStrom
>80mA (blocked fan).
Note: With temperature controller, only in standby.
unsuitable cookware - proportion of paramagnetic material
too high (e.B. aluminum).
Cooktop is released after 5s.
defective coil or coil cable (winding or ground closure)
Cooktop is released after 10s.
Real Time Clock not ready (warning is only displayed in test
mode, no longer active for newer versions)
Missing or defective Poti, value >1075
Overtemperature or missing PT1000 value > 260°C
Short-circuited PT1000 or value < -15°C
Heat sink temperature > 100°C or NTC short-circuited
Heat sink temperature < -15°C or NTC interrupted
Enable signal for output stage is missing
AC Phase-Zero < 160V
Disruption RS485 Communication
Reserve
Failure of the AC-RMS measuring module display continuous
Flashing "A" invalid application setting