16 - PROCEDURE FOR ADDING NEW RADIOCONTROL DEVICES.
If the radiocontrol devices are lost or are not operating properly, it is possible to replace
them but only under secure conditions as this operation is only allowed in particular
circumstances. If you still possess at least one of the radiocontrol devices and it is
operating correctly, proceed as follows:
1.
Disarm the system.
2.
Open a door and the bonnet.
3.
Turn on the ignition.
4.
Keep button "A" on the radiocontrol device pressed down until the direction
indicators flash and the system LED (the programming entry is confirmed).
5.
Key in the Pin Code.
6.
The system will confirm that you have accessed the self - learning procedure by
other 5 flashes of the direction indicators and by lighting up the system LED with
a steady light.
7.
Press key "A" on the radiocontrol, checking that the radiocontrol LED flashes and
that the LED on the emergency panel stops shining for approximately 1 s; the
direction indicators will also give a short flash to confirm that the radiocontrol
device has been recorded in the system's memory.
8.
Repeat step 7 for all the radiocontrol devices that you want to enable (the
radiocontrol device that was already operating must also be re-memorized by the
system).
9.
If no operation is performed for over 30 s the system automatically exits the self-
learning mode and signals that it has exited the procedure with a long flash of the
direction indicators.
10.
To exit the procedure voluntarily, it is necessary to close the bonnet. This operation
can be performed at any time.
58