Download Print this page

Cobra G100 Complete Instructions page 17

Hide thumbs Also See for G100:

Advertisement

8.8
Trunk Release (truck opening)
If the Trunk Release function is activated, with the pressure of both radio control keys to
"A" and "B" one has the trunk opening. This is signalled by a 4 s flashing of the indicator
lights, and the automatic exclusion of the internal and door ultrasound devices, and the
additional modules, too, if they are connected. When the trunk is closed the system
automatically reactivates.
8.9
• Automatic anti - theft protection delay with odometer.
If the theft protection function is controlled by a movement sensor (page 4 line 6 active in
the programming tables), at a speed other than 0, there is a delay of 4 min.; if the vehicle
stops this calculation is suspended. A cyclic sequence of alarms is generated after 4 min.
which last 4 min.. Enter the full Pin Code at this point to be recognised.
8.10
• Pager.
Negative command to control a Pager module.
8.11
• Anti - diversion block.
After the system has been disarmed by radiocontrol, if the ignition key is not turned ON
within 40 s the block is automatically rearmed.
8.12
• Anti - diversion alarm.
After the system has been disarmed by radiocontrol, if the ignition is not turned on within
40 s the system is automatically rearmed. If a door or the boot are opened, the count -
down is cancelled.
8.13
• Buzzer.
The buzzer emits acoustic signals synchronized with the blinking of the direction
lamps when the system is armed / disarmed.