Charging the battery:
NOTICE
i
i
Always disconnect the charger from the power supply
if not in use.
1. Check to make sure that voltage of mains supply is correct.
The operational voltage of the power supply unit must
match the mains supply voltage.
2. Connect charger to power supply unit.
3. Connect the power supply unit to the mains supply.
4. First position the rechargeable battery at an angle in the
charger and then fold it in until it snaps audibly into place.
5. Wait for the end of the charging process.
6. When the rechargeable battery is fully charged, push the
battery lock button and remove the battery.
7. Disconnect the power supply unit and charger from the
mains supply.
5.3.3

Replacing the respiratory filter

WARNING
!
No protection without respiratory filter!
Do not use the device without respiratory filter.
CAUTION
!
Damage to blower unit due to penetration of particles!
Make sure when you remove the respiratory filter that
no particles enter the device through the suction inlet.
NOTICE
i
i
The respiratory filter changing process may differ
depending on the respiratory filter type used.
Particulate filter
Removing the respiratory filter:
02633412.eps
1. Push respiratory filter lock button.
2. Fold out splash guard cover with respiratory filter (Figure
A).
3. Remove used respiratory filter (Figure B).
Inserting the respiratory filter:
1. Check rubber seal on respiratory filter for damage.
2. Insert new respiratory filter into splash guard cover so that
the respiratory filter is firmly seated in the splash guard
cover.
3. Hook the two lower connection points of the splash guard
cover at an angle into the fan unit sockets.
X-plore 8000
A
4. Fold splash guard cover in until it audibly snaps into place
at the filter lock button.
Chemical cartridge or combination filter
Removing the respiratory filter:
1. Push respiratory filter lock button.
2. Fold out respiratory filter with splash guard cover (Figure
A).
3. Dismantling the splash guard cover:
a. Press on the centre of the upper splash guard cover
edge until it snaps out.
b. Fold out splash guard cover (Figure B).
Inserting the respiratory filter:
1. Check rubber seal on respiratory filter for damage.
2. Place splash guard cover with its lower edge at an angle on
the respiratory filter.
3. Push on splash guard cover until it snaps audibly into place.
4. Hook the two lower connection points of the respiratory
filter at an angle into the fan unit sockets.
5. Fold respiratory filter in until it audibly snaps into place at
the filter lock button.
5.3.4

Check the flow rate and warning devices

1. Make sure that a respiratory filter is inserted (see section
5.3.3 on page 13).
2. Connect the plug-in connector of the breathing hose to the
blower unit.
3. Switch on the blower unit by pushing the
control panel.
After switching on, the device performs a self-test. Correct
malfunction if the device fails to work properly or warning
devices are triggered (see section 4 on page 11).
4. Cover open end of the breathing hose with hand.
The blower unit starts to run faster after approx. 5 seconds.
After approx. 20 seconds an alarm is triggered.
B
Have the blower unit checked if the blower speed remains
02733412.eps
unchanged and no alarm is triggered.
5. If you wish, you can switch off the blower unit by pushing
the
button on the control panel again.
5.3.5
Replacing the O-ring at plug-in or bayonet-type
hose connector
1. Use the O-ring removal tool to lift the old O-ring out of the
groove.
2. Insert new O-ring in the provided groove.