1.2 Front Panel

MSP329 TX
No.
Name
Description
POWER
1
Indicator
STATUS
2
Indicator
MODE: use this switch to toggle between normal and debug modes.
Working
3
Mode
Switch
DIP: this DIP switch consists of four manual switches, which are used to route
Link
DIP
audio, video together with IR, and USB signals between MSP329 TX and MSP329
Switch
RX based on their positions. By default, each individual switches is in the up
4
position. For more information, see "Using DIP Switch to Perform Routing".
1
2
3
4
Note:For the DIP switches in both encoder and decoder, changes to them take
O N
D I P
effect immediately without rebooting the system.
MSP329
On
MSP 329 TX is powered on.
Off
MSP 329 TX is powered off.
MSP 329 TX is connected to both an active video source and MSP
Solid On
329 RX.
MSP329 TX is disconnected from an active video source.
Blinking
MSP329 TX is disconnected from MSP329 RX.
MSP329 TX is powered off.
MSP329 TX is in the boot process.
Off
Network is down.
In this mode, you can connect the rear panel RS232 port to a RS232
NORMAL
device such as a computer for bi-directional serial communication
(Default)
with a RS232 device on the IP controller side.
In this mode, you can connect the rear panel RS232 port to a RS232
DEBUG
device such as a computer for debugging MSP329 TX.