Harvia Sentiotec home.com4 BLACK Instructions For Installation And Use Manual page 12

Sauna control unit
Hide thumbs Also See for Sentiotec home.com4 BLACK:
Table of Contents

Advertisement

Instructions for installation and use
p. 12/64
Two-sensor mode with bench sensor (F2)
In two-sensor operation with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity is timed. Only the set val-
ue for the humidity level (in % of relative humidity) is displayed by the sauna
control unit. The actual humidity level in the sauna room when humidity is timed
depends on the size of the room and the vaporizer capacity and may deviate
from the set value.
Two-sensor mode with humidity temperature sensor (FTS2)
When a humidity temperature sensor is used in two-sensor mode, the sauna
control unit displays the temperature which is measured by the humidity tem-
perature sensor as the actual temperature.
In two-sensor mode with humidity temperature sensor, the vaporizer is regulated
in accordance with the humidity level measured in the sauna room. The actual
value for the humidity level (in % of relative humidity) is displayed by the sauna
control unit.
If a humidity temperature sensor is connected, the "vaporizer" menu item cannot
be hidden.