Inverter / Charger Model
Multiplus 48/500/6
Multiplus 48/800/9
Multiplus 48/1200/13
Multiplus 48/3000/35
Multiplus 48/5000/70
Quattro 48/8000/110-100/100 6500
Quattro
48/10000/140-100/100
Quattro
48/15000/200-100/100

3. CAN-bus Wiring

You can connect multiple battery modules together to form a single large battery by connecting the
RJ-45 cable supplied by Pylontech using the link ports on the battery. This is shown in more detail in
the
example wiring diagram
The batteries will automatically detect and link to each other, no adjustment of dip switches or
software changes are necessary on the batteries.
The battery with the empty link port 0 is the master battery. You must use the VE.Can to CAN-bus
BMS type B Cable, part number ASS030720018, you cannot use the cable supplied by Pylontech.
Victron Energy - https://www.victronenergy.com/live/
3/11
Inverter
Inv
peak
continuous
watts
watts @ 25
surge
degrees
rating
430
900
700
1600
1000
2400
2400
6000
4000
10000
16000
8000
20000
12000
25000
and Pylontech manual.
Victron & Pylontech US2000, US3000 and Phantom-S
Battery
Number of
continuous
Pylontech
discharge
modules
watt rating
1
1200
1
1200
1
1200
2
2400
4
4800
6
7200
7
8400
10
12000
Battery
peak
discharge
watt rating
4800
4800
4800
9600
19200
28800
33600
48000