Input/Output Function Category - Siemens SIMATRIX Programming Manual

Table of Contents

Advertisement

Programming keyboards
6.4.1

Input/output function category

42
Siemens Building Technologies
Fire Safety & Security Products
When you select a function within a function category, a brief explanation and the
current parameter settings will appear in the display window. Many functions allow
the input of extra parameters in the display window (e.g. the video output number).
In the function description, this icon indicates the label that is used in the parameterisation
software to illustrate the programmed key/keyboards. We recommend you also use this
label for the actual keyboards. Where applicable, x stands for a selected value.
The following basically applies if a key has been allocated a function that requires additional entry via
the digit keys:
First input the value (max. 255) using the digit keys,
then press the function key; never in reverse order!
For example:
Switching camera 15 to monitor 7.
1.
Program a key with the Input/preselect function (without entering the number
of the video input) and another key with the Output function (without setting
the number of the video output).
2.
Now enter 1 and 5 using the digit keys and press the Input/preselect key.
3.
Now enter 7 using the digit keys and then press the Output key.
Camera 15 will be switched to monitor 7.
When supplied, the key lettering of the keyboards corresponds to the parameter settings of
keyboard 1. The lettering on the other keyboards must be modified to suit the parameter settings.
Fig. 33
Input/output function category
Input/preselect
This function will normally preselect a set video input for display. It is however
possible to combine the programmed preselection with other functions.
In –>
Z
Z
Z
Funktions
-
06.2008