Siemens Building Technologies
Fire Safety & Security Products
Assigning keyboard inputs to monitors
A monitor (arrow keys) that displays entered data can be assigned to each
keyboard. Enter the corresponding monitor for each keyboard here. Keyed-in data
will not be displayed if no output is allocated (Monitor 0). The data entry from more
than one keyboard can be displayed on the same monitor.
Lost signal indication (only with NEO V2 )
If this option is selected in case of a video signal lost a dark controlled picture is
switched to the keyboard monitor and the camera text of the lost signal is shown
on the screen.
Status message removed after x seconds
The start—up message that follows a power-on reset or system reset, which
appears on all the monitors connected to the system, can be erased after a preset
period of time. If this setting has not been activated, the start-up message will
remain on display until the first image appears.
Status message removed after x seconds
Automatic start-up message erasure not enabled
The status message will remain on display until the first image appears.
Use the arrow keys to enter the settings.
Index card for SUT 48 Display
Fig. 15
SUT 48 display
Use this index card to indicate which SUT 48 keyboards will activate the screen for
displaying the characters that are keyed in.
If connection has been made via a serial interface (COM2 to COM4), the SUT 48 display is not active
as no data transfer will take place between the video matrix and the keyboard.
User display information
27
06.2008