Maintenance Manual
NOTE: Refer to the
Read the instructions in this manual before beginning installation. Save these
instructions and refer to them for inspection, maintenance, and troubleshooting
information.
For questions regarding the operation, installation or maintenance of this product, visit bradleycorp.com or call
800.BRADLEY (800.272.3539).
Product warranties and parts information may also be found under "Resources" on our website at
bradleycorp.com.
P20-225 Rev. A: ECO 19-15-015A
© 2020 Bradley
Page 1 of 19
2/12/2020
Installation and
Installation and Maintenance Manual, P20-224
Verge
Multi-Feed Soap Tank
®
Verge
Soap Dispenser
®
Verge
Soap Dispenser - Metro Series (6-3300)
®
Verge
Soap Dispenser
®
Verge
Soap Dispenser
®

Table of Contents

Safety Information ............................................................... 2
Supplies Required ............................................................... 2
Components ........................................................................ 3
Dimensions .......................................................................... 4
Soap Spout Mounting .......................................................... 5
Control Box Mounting .......................................................... 6
Control Box & Soap Supply Connections ............................ 7
Multi-Feed Soap Tank Assembly Mounting ......................... 8
Soap Supply Connections ................................................. 12
Power Supply Connections ................................................ 16
Operation Mode ................................................................. 18
Cleaning and Maintenance ................................................ 19
for individual automatic top-fill soap dispensers.
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
-
Crestt Series (6-3100)
-
Linea Series (6-3500)
-
Zen Series (6-3700)
P.O. Box 309
+1 262 251 6000
bradleycorp.com

Advertisement

Table of Contents
loading

Summary of Contents for Bradley Verge Crestt Series

  • Page 1: Table Of Contents

    Product warranties and parts information may also be found under “Resources” on our website at bradleycorp.com. P.O. Box 309 P20-225 Rev. A: ECO 19-15-015A Menomonee Falls, WI 53052 USA © 2020 Bradley 800 BRADLEY (800 272 3539) +1 262 251 6000 Page 1 of 19 2/12/2020 bradleycorp.com...
  • Page 2: Safety Information

    Caution A DC plug-in adapter (supplied by Bradley) should be used in conjunction with the Bradley soap dispenser products. The DC plug-in adapter supplied by Bradley is 6V DC regulated. Direct connection to 120V/22V 50/60Hz could result in personal injury and will damage the sensor.
  • Page 3: Components

    Silicone Washer Battery Pack Locking Tab w/Batteries Wing Nut AC Adapter Splitter Assembly Multi-Feed Cap & Ring Multi-Feed Control Box Soap Pump (Liquid w/Tube) Soap Pump (Foam w/Tube) Multi-Feed Soap Tank Assembly Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 4: Dimensions

    2¹¹⁄₁₆" (93) (100) (68) 6-3100 Crestt Series 6-3300 Metro Series 4³⁄₄" (120) 4⁷⁄₈" (123) 4¹⁄₈" (104) 3⁵⁄₁₆" 4³⁄₁₆" (84) 2¹³⁄₁₆" 2³⁄₁₆" 4³⁄₁₆" (106) (71) (55) (106) 6-3500 Linea Series 6-3700 Zen Series Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 5: Soap Spout Mounting

    Soap Supply Feed the soap supply and LED & sensor wires through the opening in the locking tab. Thread the wing nut onto the shank. Torque to 24 in/lb. Wing Nut Key Way Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 6: Control Box Mounting

    Mounting suitable mounting hardware) to attach the Screws control box assembly in place. Appropriate fastener anchors and mounting hardware must be used when mounting the control box assembly in the desired surface. Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 7: Control Box & Soap Supply Connections

    LED Connection from Soap Make the IR sensor and LED, Spout Assembly connections as shown. Connections are NOT interchangeable. Press the soap supply tube over the soap pump connection as shown. Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 8: Multi-Feed Soap Tank Assembly Mounting

    Thumb Screws Mounting Bracket Slide the soap tank downward from the bracket Soap assembly to remove the soap tank from the Tank mounting bracket. Lower Soap Tank Bracket Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 9 Insert the fill port cap into the fill port ring. Use the 3 mm Allen wrench (provided with spout assembly) to secure fill port cap in place. Fill Port Ring Fill Port Screws Fill Port Screws Fill Port Hub Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 10 Be sure to align the thumb screw holes. Insert the four thumb screws into the mounting bracket to hold the soap tank assembly in place. Thumb Screws Lower Soap Tank Bracket Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 11 Installation Verge Multi-Feed Soap Tank ® Reconnect Soap Sensors & LED Connector Power Supply Connection Soap Overflow Sensor (Black) LED Connector (White) Low Soap Level Sensor (Red) Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 12: Soap Supply Connections

    (located at the end of the soap supply system). Install the soap supply valve in the proper flow direction as shown on the valve. Use the extra tubing when cleaning and/or maintaining the soap system. Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 13 Installation Verge Multi-Feed Soap Tank ® Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 14 (located at both ends of the soap supply position. system). Install the soap supply valve in the proper flow direction as shown on the valve. Use the extra tubing when cleaning and/or maintaining the soap system. Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 15 Installation Verge Multi-Feed Soap Tank ® Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 16: Power Supply Connections

    The multi-feed soap tank assembly and each of the control boxes require a power supply connection. The power supply can be a Bradley supplied battery pack, a single AC adaptor, or an AC adapter splitter assembly kit (see page 3), depending on the selection made at time of purchase.
  • Page 17: Adding Soap To Multi-Feed Soap Tank Assembly

    90% capacity. Fill Port Hub Assembly Replace the fill port cap into the fill port hub assembly and hand-tighten. Initial installation requires multiple activations to prime each soap spout dispenser. Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 18: Operation Mode

    LED flashes red Low soap Soap dispensing is enabled intermittently LED becomes steady red 2.5 seconds Overfill protection with audible indicator LED flashes red/green 0.5 seconds First time powering up the system Bradley • P20-225 Rev. A: ECO 19-15-015A 2/12/2020...
  • Page 19: Cleaning And Maintenance

    Generally, any quality soap meeting the viscosity and pH guidelines above will work well with Bradley soap dispensers. PCMX or Isopropanol based antibacterial soaps (within viscosity and pH limits) will also work with Bradley dispensers. Soaps satisfying these basic guidelines will provide consistent flow and reduce clogs.