Operation Mode

Operation mode is the normal dispensing mode automatically activated when the soap dispenser is in use. All of the sensors are
active in this mode.
While in operating mode:
• Soap is activated when IR sensor is triggered.
• When the voltage of the battery is lower than 4.6V ±0.2V for 7–10 seconds, the low power LED indicator flashes
green/green and soap dispensing stops.
• When the soap level is below 25% capacity, the low soap LED indicator flashes red.
• When filling the soap fill port with soap, the overfill protection LED indicator becomes steady red and audible indicator
sounds when the tank is at 90% capacity.
LED Indicators
LED flashes green
LED flashes green/green
LED flashes red
LED becomes steady red
with audible indicator
LED flashes red/green
18
Duration
1 second
ON:
1.2 seconds (green for 0.5 seconds, pause for
0.2 seconds, green for 0.5 seconds)
OFF: 2 seconds
ON:
0.2 seconds
OFF: 2 seconds
Soap dispensing is enabled intermittently
2.5 seconds
0.5 seconds
2/12/2020
Meaning
Dispensing soap
Low power
Low soap
Overfill protection
First time powering up the system