Technical Data; Io-Box32 - Bosch IO-BOX32 Manual

Table of Contents

Advertisement

7

Technical data

7.1

IO-BOX32

1070 072 302-101 (01.06) GB
Technical data
corresponds to the standards
Spring terminal
Terminal range
D "e" one-wire H05(07) V-U
D "f" fine-wire H05(07) V-K
D "f" with wire terminating sleeve
complying with DIN 46228/1
D AWG conductors
D Insulation diameter
Voltage supply
complying with EN 61 131-2
D Rating
D permitted range
D superimposed AC
Current consumption from 24-V
logic and sensor supply US
D Only logic supply
D Sensor supply per input byte
Current consumption from the 24-V
load supply U1
Current consumption from the 24-V
load supply U2
Reverse polarity protection
Insulation testing voltage
Basic insulation
IO-BOX32
D EN 61 131-2
corresponds to IEC 1131-2
D EN 61 131-2/A11
D EN 50 178
corresponds to VDE 0160
D EN 60 204-1
corresponds to VDE 0113, Part 1
D EN 50 081-2
corresponds to VDE 0839, Part 81-2
D EN 50 082-2
corresponds to VDE 0839, Part 82-2
D EN 60 529
corresponds to DIN VDE 0470-1
D EMC law of 25.09.1998
as well as revisions
0.08 to 1.5 mm
2
2
0.5 to 1.5 mm
2
0.5 to 1.5 mm
2
0.5 to 1.5 mm
28 to 16
Diameter v2.9 mm
24 V DC
20.4 to 28.8 V DC
v5 %
absolute limits: 19.2 to 30.0 V
approx. 0.1 A
0.5 A (no short circuit)
8 A (no short circuit)
8 A (no short circuit)
All supply voltages are reverse-connect
protected
with measurement voltage v50 V
D 350 VAC
D 500 V DC
D 500 V impulse peak 1.2/50 µs
7–1

Advertisement

Table of Contents
loading

Table of Contents