An alarm percentage can be set in order to get a warning before exceeding the allowed threshold limit.
The 100% percentage correspond to the real standard value.
In the screen below, setting the "Percent" value at 80% will raise an Alarm 1 at 80% of the allowed
DIN4150-3, Vibration at foundation for Industrial Buildings acceptable limit.
3.4.5 Advanced settings
The ADVANCED SETTINGS tab allows the following ROCK parametrization:
Synchronization Rock-SCS
Device configuration
Figure 17: Alarm percentage warning
Synchronization to the SCS initiated by the ROCK every 5 to
1440 minutes (1day). Default is 60 minutes – 1h.
The background data will be pushed to the SCS at that time and
the ROCK parameters will be updated if modified after the
previous synchronization.
Note that shorter synchronization time will lead to higher power
consumption and reduce device autonomy.
However it is important to understand that the ROCK is
synchronized to the SCS every time an event is generated
regardless of the synchronization time set.
A configuration name should be given and this allows to "Save"
or "Load" typical device configurations. It is then easier to setup
multiple ROCK devices with always the same parameters.