Chimney Sweeper Function - elco TRIGON L Operating Manual

Table of Contents

Advertisement

Chimney Sweeper Function

Control Valve Stop Function
Description of Chimney Sweeper
Function
The chimney sweeper function enables
a commissioning of the boiler while in
heating mode. It serves to take
measurements at the boiler, with the
system being set to maximum heating
output until the temperature monitor is
triggered. In order to enable the largest
amount of heating output possible, the
chimney sweeper function forces a
signal to extract heat.
Trigger
Simultaneous activation of buttons for
more than 3 sec, but less than 6 sec.
The display flashes the chimney
sweeper symbol .
Function
Generates a forced signal to output
heat.
Deactivates the PID and 2-point con-
troller
Output of maximum heating perfor-
mance
Message code is triggered during an
active chimney sweeper funct.
Terminate
Activate buttons
or
Transition to controller stop funct.
During transition to/from error position
Description of Control Valve Stop
Function
The control valve stop function enables
a manual setting of the boiler output
during heating mode. It serves to take
measurements at the boiler.
Clock Function
The timer must be set to the proper
time in order to provide a proper
heating program.
The current time is set as described
on the previous page
(Parameterization End User)
Effect
Clock is set to the current time.
The proper setting is important so that
heating and domestic use water
program can function properly.
Notes
Clock continues to run during the
adjustment process.
During the clock adjustment process,
each activation of
or
resets the seconds to zero.
Trigger
Activate
buttons
longer than
6 sec.
The display flashes
the control valve stop
symbol.
The display shows the specified rela-
tive boiler output.
Description of Domestic Use Water
Provision
The provision of domestic use water
can be switched on or off independently
from the other operating modes.
Operating Mode
The domestic use water operating
mode is turned ON or OFF by activat-
ing the domestic use water provision
button .
Effect
Domestic use water provision turned
ON is indicated by a bar below the
domestic use water symbol .
Domestic use water is the provided
automatically according to the internal
specifications. Domestic use water
provision turned OFF is indicated by a
deleted bar below the domestic use
water symbol.
Functions upon Attached Room
Device QAA73 (Accessory)
If a room device is connected to the
TRIGON, all functions supported by
same are either locked out or blocked
out by the AGU2.311 panel.
These are, for example:
Clock setting at AGU2.311 operating
panel (display only)
Timer programs
Target values
Parameterization via the operating
panel is still possible!
Backlight
Upon activation of any button, the
backlight is activated for a period of
approx. 8 minutes.
Function
Generates a forced signal to output
heat.
Deactivates the PID and 2-point con-
troller.
Output of starting performance.
Settings
Push the set buttons to increase/
decrease the output in per-
centage steps.
Push the line selector buttons to alter-
nate between minimum and
maximum output.
en