Gas condensing boiler TRIGON XXL Models and output Application possibilities Value propositions Models and output Application possibilities Value propositions The floor standing gas condensing The gas condensing boiler TRIGON Unique reliability boiler TRIGON XXL is available in 3 XXL is applicable for alle central hea- proven technology with exceptional different ranges SE, ECO and EVO.
Gas condensing boiler TRIGON XXL Technical description Technical Description chimney connection. The LMS14 control unit can con- The TRIGON XXL is a fully modulating trol the boiler operation based on: condensing boiler. The control unit of The return water from the system en- Boiler control (stand alone the boiler adapts the modulation ratio ters the boiler in the lower section,...
Technical description Declaration of conformity Declaration of Conformity ELCO BV, Hamstraat 76, 6465 AG Kerkrade (NL), Declares that the product TRIGON XXL Is in conformity with the following standards: EN 15502-1 EN 15502-2-1 EN 55014-1 / -2 EN 61000-3-2 /-3...
Extent of delivery Standard boiler Boiler transport Boiler installation Standard boiler A boiler delivery package contains the following components: Component Package Pcs. Boiler fully assembled and tested On wooden pallet, sealed in PE foil Cardboard box on top of heat exchanger Syphon + dirt seperator for condensate connection (under casing) Operation and Installation manual...
Norms and regulations General regulations Application Norms and regulations Additional national standards General regulations This boiler is CE approved and applies EN 60335-2-102 Household and This documentation contains to the following European standards: similar appliances - Safety - Part 2- important information, which is a base 102: Particular requirments for gas, for safe and reliable installation, com-...
Norms and regulations Maintenance Fuel Combustion air Water quality Maintenance Fuel Combustion air Regular maintenance is necessary to The gas condensing boiler TRIGON The gas condensing boiler TRIGON secure a safe and economical operati- XXL is applicable for gases G20, G25, XXL can be used in both non- on of the installation.
Norms and regulations Noise protection Antifreeze Noise protection The TRIGON XXL is supplied with ad- The gas condensing boiler TRIGON justable wheels, which also prevent the XXL is equipped with a patented transmission of vibration noise from the premix burner. The noise level of this boiler into the building.
Flue gas system Requirements and regulations Materials Requirements and regulations Pay attention to the following The installer is responsible to apply the Regulations for the construction of flue recommendations when dimensio- correct diameter, length and type of flue gas systems are very different for each ning a flue gas system: gas system.
Flue gas system Flue gas data Flue gas data °C TRIGON SE 650 300 ±1 309,9 84,4 SE 750 350 ±1 346,1 94,0 SE 850 350 ±1 404,8 109,8 SE 1000 1038 400 ±1 458,2 124,7 SE 1100 1073 1159 400 ±1 511,6 139,1...
Flue gas system Dimensioning Dimensioning When dimensioning a flue gas system, it’s necessary to perform a calculation check of the flue gas system in order to verify if the choosen system is applicable. The following tables represent as an example of possible flue gas systems of TRI- GON XXL SE, EVO and ECO series, including the maximum possible height of the system.
Neutralisation General Neutralisation systems Standard neutralisation system (DN) Neutralisation system with pump (HN) General The maximum amount of condensate Condensate, created by the TRIGON for each boiler type can be found in the XXL, should be drained into the public chapter „Technical data“.
Hydraulic connection Hydraulic resistance ∆T-measurement ∆p-measurement Water flow data TRIGON XXL SE Hydraulic resistance ∆T-measurement ∆p-measurement The hydraulic resistance depends on Check the temperature difference over Check the pressure difference over the the flow rate through the boiler and the the boiler (∆T flow-return) when the boiler (∆p flow-return) when the boiler boiler type.
Hydraulic connection Water flow data TRIGON XXL EVO TRIGON XXL EVO 100,0 EVO 700 EVO 800 EVO 900 EVO 1000 EVO 1100 EVO 1200 EVO 1400 10,0 EVO 1550 EVO1700 90,0 Flow rate [m³/h] TRIGON XXL EVO 1000 1100 1200 1400 1550 1700...
Hydraulic connection Hydraulic connection into a system Standard Bypass Hydraulic connection into a system Details to the 3 possibilities mentioned Standard, with low loss header or The TRIGON XXL must be connected above, can be found in the next sec- plate heat exchanger in such a way, that a minimum flow rate tions.
Controls Basic controls and connections Control by building managemant system Boiler enable signal Temperature or capacity setpoint Basic controls and connections Electronic high limit thermostat Weather compensation (with optional The standard version of the TRIGON outdoor sensor) Electronic flue gas temperature limiter XXL is equipped with a LMS14 boiler ...
Controls Capacity feedback signal OK/Alarm output signal Capacity feedback signal, terminals 120-121 (0-10VDC) Capacity feedback This signal is available at the mentio- ned terminals, when the burner is acti- ve. The following graph shows the valu- e of the signal. Attention: max.
Controls Heating zone control Cascade control Heating zone control Cascade control The TRIGON XXL can be extended The TRIGON XXL can be controlled in with an AVS75 controller for extended a cascade system of maximum 8 boi- heating zone control. The AVS75 enab- lers.
Accessories System selection System selection The TRIGON XXL is supplied from the The plug & play accessory kits factory with LMS14 boiler management enable a very easy selection and unit. Additional a wide variation of acces- assembly of a complete system sory kits is available.
Accessories Safety devices 2x max. Water pressure switch + Max. gas pressure switch External high limit thermostat pressure gauge The kit includes a gas pressure There is a connection point for the The pre-assembled kit can be con- switch, which can be connected di- high limit stat on the boiler flow pipe.
Accessories Hydraulics Plate heat exchanger + connection The kit contains a plate heat ex- changer including connection materi- al, automatic de-aerator, expansion vessel and flow pipe. The following data can be used for the dimensioning of the secundary system. ΔT=10K ΔT=15K ΔT=20K TRIGON XXL...
Accessories Hydraulics Low loss header + connection kit Duo header The kit contains a duo header inclu- Mono header ding automatic de-aerator, plunge (for The kit contains a low loss header in- header sensor) and fill/drain valve on cluding connection material, automatic the bottom connection.
Page 38
Accessories Hydraulics SAP Code 12034679 12034690 12034701 3581392 A Diameter B Total height [mm] 2400 2400 2400 2400 C Height to boiler return [mm] 1065 D Boiler flow/return distance [mm] 1080 1080 1080 E Header body height [mm] 2270 2270 2270 2270 F Height to system return...
Accessories Hydraulics Flow adapter + NRV 2nd Return connection 2x Bends 90° The kit contains a flow adapter The kit contains a pipe which can be The kit contains 2 90° bends to allow (extension part for the flow pipe) and used as 2nd (hot) return connection a flexible set up.
Accessories Controls RECEIVER AVS71.390/109 WIREL- OUTDOOR SENSOR ROOM CONTROLLER ESS The kit contains an AVS71 AVS13.399.201 WIRELESS QAA75.610/101 wireless receiver. When connected to The kit contains an outdoor sensor The kit contains a QAA75 room unit, QAC34 and a wireless transmitter which communicates with the boiler boiler, it can transmit data between AVS13.
Accessories Controls HEADER/HOT WATER SENSOR Heating zone sensor QAD36 OUTDOOR SENSOR QAC34.101 QAZ36 CABLE 6M The kit contains a clamp sensor The kit contains an outdoor sensor The kit contains a header/hot water QAD36 with 4m cable. QAC34. sensor QAZ36 with 6m cable and a 1/2"...
Accessories Other Gas filter Gas pressure regulator 100mbar Air filter The kit contains a gas filter which can + connection kit The kit contains an air filter which can be connected directly to the gas pipe The kit contains a gas pressure regu- be connected directly to the air intake of the boiler.
Installation examples 2-A-C: 1 heating zone + low loss header 2-A-C: 1 heating zone + low loss header elco Description TRIGON XXL with low loss header Weather compensated control 1 mixed heating zone Tips Complete accessory kits with low loss header are available for ∆T=10-20K...
Installation examples 2-5-A-C: 1 heating zone and sanitary hot water + low loss header 2-5-A-C: 1 heating zone and sanitary hot water + low loss header elco Description TRIGON XXL with low loss header Weather compensated control ...
Installation examples 4-A-C: 2 heating zones + low loss header 4-A-C: 2 heating zones + low loss header elco Description TRIGON XXL with low loss header Weather compensated control 2 mixed heating zones Tips Complete accessory kits with low loss header are available for ∆T=10-20K...
Installation examples 4-5-A-C: 2 heating zones and sanitary hot water + low loss header 4-5-A-C: 2 heating zones and sanitary hot water + low loss header elco Description TRIGON XXL with low loss header Weather compensated control ...
Installation examples A-C: Boiler control via 0-10VDC + low loss header A-C: Boiler control via 0-10VDC + low loss header elco Description TRIGON XXL with low loss header Tips Complete accessory kits with low loss header are available for ∆T=10-20K (see chapter „Accessories“).
Installation examples B-C: Boiler control via 0-10VDC + plate heat exchanger B-C: Boiler control via 0-10VDC + plate heat exchanger elco Description TRIGON XXL with plate heat exchan- Tips Complete accessory kits with plate heat exchanger are available for ∆T=10-20K (see chapter...
Installation examples 4-5-A-C-E: 2 heating zones and sanitary hot water + cascade via low loss header 4-5-A-C-E: 2 heating zones and sanitary hot water + cascade via low loss header elco elco Description 2x TRIGON XXL with low loss header ...
Installation examples Extension 2 heating zones Extension 2 heating zones Logon B Description Weather compensated controller with wall hung box LOGON B Extension of 2 heating zones Tips The extension controller should al- ways be used in combination with the integrated boiler controller LMS14 ...
Technical Data Country specific Germany/Austria/Switzerland: EnEV (Anlagenaufwandzahl, DIN V4701-10) TRIGON XXL SE 1000 1100 1200 1300 1500 1700 1900 Nominal heat output at 80/60°C 649,7 725,6 848,7 960,7 1072,7 1183,7 1295,7 1480,8 1665,9 1851,0 Nominal heat output at 40/30°C 656,6 733,3 857,7 970,8...
Page 57
Technical Data Country specific Italy: Legge 10 TRIGON XXL SE 1000 1100 1200 1300 1500 1700 1900 Combustion efficiency (indirect) at 92,3 92,3 92,3 92,3 92,3 92,3 92,3 92,3 92,3 92,3 80/60°C full load (burner on) Combustion efficiency (indirect) at 97,7 97,7 97,7...
Page 58
Technical Data Country specific Italy: Legge 10 TRIGON XXL ECO 1050 1150 1300 1450 1600 Combustion efficiency (indirect) at 93,7 93,7 93,7 93,7 93,7 93,7 93,7 93,7 93,7 80/60°C full load (burner on) Combustion efficiency (indirect) at 97,7 97,7 97,7 97,7 97,7 97,7...
Page 59
Technical Data Country specific Italy: Legge 10 TRIGON XXL EVO 1000 1100 1200 1400 1550 1700 2000 Combustion efficiency (indirect) at 97,7 97,7 97,7 97,7 97,7 97,7 97,7 97,7 97,7 97,5 80/60°C full load (burner on) Combustion efficiency (indirect) at 98,0 98,0 98,0...
Page 60
Technical Data Country specific RT2012 (France only) TRIGON XXL SE 1000 1100 1200 1300 1500 1700 1900 Nominal heat output at 80-60ºC 649,7 725,6 848,7 960,7 1072,7 1183,7 1295,7 1480,8 1665,9 1851,0 Minimal heat output at 80-60ºC 164,0 182,7 213,4 242,3 270,3 298,2...
Page 61
Technical Data Country specific RT2012 (France only) TRIGON XXL EVO 1000 1100 1200 1400 1550 1700 2000 Nominal heat output at 80-60ºC 638,9 747,5 846,3 945,1 1043,0 1140,8 1304,2 1466,6 1630,0 1953,0 Minimal heat output at 80-60ºC 182,1 212,3 240,6 268,8 297,1 324,3...
Page 62
Technical Data Country specific UK specific data TRIGON XXL SE 1000 1100 1200 1300 1500 1700 1900 Efficiency at 80/60ºC full load Gross 83,4 83,4 83,4 83,4 83,4 83,4 83,4 83,4 83,4 83,4 Efficiency at 50/30ºC min load 92,4 92,4 92,4 92,4 92,4...
Page 63
Technical Data Country specific UK specific data TRIGON XXL EVO 1000 1100 1200 1400 1550 1700 2000 Efficiency at 80/60ºC full load Gross 88,1 88,1 88,1 88,1 88,1 88,1 88,1 88,1 88,1 88,0 Efficiency at 50/30ºC min load 97,4 97,4 97,4 97,4 97,4...
Norms Germany: Austria: Italy: Sicurezza degli impianti DIN EN 483 ÖNORM H 5152: Brennwert- Feuerungsanlagen, Planungshilfen Legge 5 marzo 1990 n. 46 DIN EN 677 ÖNORM M 7443: Gasgeräte mit D.P.R. 6/12/91 n. 447 DIN EN 13384-1 ...