IDEAL MSC-18K-B Manual page 28

18,000 lb mobile single column lift
Table of Contents

Advertisement

FAULT
POSSIBLE CASE
Oil level in tank too low.
Column
Does not
Lift
Pump drawing-in air.
Properly.
The steel plug has not been
replaced by the breather cap
Breather cap blocked.
Column
Height
Reading
Sensor zero point not
not
correct
Reach
Zero
Fuse blown.
No
Power switch is OFF.
Control
Power
Broken cable or loose
connector.
The emergency stop button
has not been unlocked.
FAULT
POSSIBLE CASE
No power supply.
No
Power
Main fuse blown.
(Power
Indicator
Main switch(es) OFF.
are Off)
REMEDY
Add oil as necessary; refer to lubricating
instructions on lifting column.
Tighten the suction filter fastening or crimp
tighter.
Install the breather cap
Clean breather cap.
Do encoder alignment
Check the fuses F1, F2 and F3. If necessary,
replace the fuse(s) in the control box. If fault
occurs again, contact the Service
Department.
Set power switch to ON.
Check cable and connector.
Release the emergency button. Set the main
switch(es) to OFF and ON.
REMEDY
Have fault corrected by qualified electrician.
Replace fuse.
Set power switch(es) ON.
27
Mar 2016
MSC-18K