IDEAL MSC-18K-B Manual page 23

18,000 lb mobile single column lift
Table of Contents

Advertisement

4.5 OTHER MESSAGES EXPLAINING
MESSAGE
PLC err, check &
1
repower
Encode
2
WHEEL/AXLE!
Asynch! WHEEL /
3
AXLE mode
4
24Vdc insufficient
Locked by abnormal
5
ope.
Stop!
6
Manual adj.! Max.
7
<5s / time
Reset !
xx time
8
xx min.
Reach end of travel
9
EXPLAINATION
a. Communication between master and slave columns failed. (bad
cable connection, antenna problem or some PLC lack of
power.)
b. Some PLC not working
Note: must be power off for checking then power on again
err,
a. Some encoder is not working ( not powered, bad wired or in
error
b. Bad communication( wireless model)
a. Too big difference in height reading (>1700mm), caused by
over turning
b. Some column not move (motor not running, carriage locked)
c. Some encoder not turning( belt left the gear)
After moving stopped, one or more columns were found battery in
low voltage. The lift will not raise up any more but may lower
down.
One button is pressed within 2' after previous button is released.
a. Emergency button is pressed.
b. Communication between columns is broken.
c. One or more column is power off.
d. Within 2 second after button is released.
Manually adjust column height. Maximum single operation for 5
seconds per time..
RESET state: one lift height is below 5 cm when in ALL mode. Lift
will be back in ZERO bias.
Free movement is possible and pair of column can be added or
taken away.
Any operation will leave this RESET state.
One column stops after reaching its height limit. (this column will
not raise when lower down)