6.3 YEARLY (BY OPERATOR)
-Clear the filter/mesh of the electro-magnet valve pin on the motor pump.
(Refer to special steps provided following)
- Change the hydraulic oil every two years.
6.4 CLEANING & CHANGE OIL (BY OPERATOR)
- Cleaning reminding
Motor pump running time (up and down) accumulates up to 300 minutes since new
machine be operated first time, the software will present a special displaying
(following) to remind user to do the filer clearing of the valves and hydraulic oil
changing.
And also while the time reaches 3600 minutes, it will appear again.
To continue operation, just press ESC button twice.
6.5 CHANGE OIL
- Change the oil.
(1)
Lower the lift completely to floor.
(2)
Remove the oil from the tank.
(3)
Refill with approximately 10.5 Liters of hydraulic oil meeting AW32 or 46,
filtrated to 4 Micrometer.
(4)
Check the oil level in oil tanks on each column, add if necessary.
TB-6 Controller
By KERNEL Right Reserved
Run
, Peri Check
301 min
Push ESC twice to go on
th
LCD display 18
Mar 2016
MSC-18K
V6.84MD
25