3.5 TRAVEL DISTANCE, HEIGHT UNIT AND UNIFORM CHANGING
3.5.1 TRAVEL DISTANCE AND HEIGHT UNIT CHANGE
If the lifting height is less than 67" (170cm) due to low shop ceiling, the travel distance
shall be set in following steps before starting the lifting operation.
1. After power on, waiting the LCD screen to be the LCD screen 4th, then press ESC
button to change into system menu. ( LCD screen 5
2. When 'USER MENU' is high-lighted, press ENTER button to enter the sub menu of
USER MENU. ( LCD screen 6
USER MENU
OPERATOR MENU
DIAGNOSTICS MENU
RELEASE PASSWORD
LCD screen 5
3. Press DIRECTION DOWN button to move to 'Set of Unit/Stroke' as in LCD screen
th
6
.
4. Press ENTER button again to enter the unit and travel distance modification screen.
th
(LCD screen 7
)
5. To change the unit, using 'DIRECTION' UP and DOWN buttons to change the
number on the right-up corner. '1' refers to inch. '0' refers to cm.
6. To change the travel distance, using 'DIRECTION' buttons and to move cursor to the
percentage on the screen then change the number.
Note: The percentage range is 60%--100%. Min. step is 2" (5cm).
7. Press ENTER to confirm the modification and press ESC to exit this function to
upper menu. (LCD screen 6
8. Press ESC button twice to get back to LCD display 4
th
)
th
Unit: 0—cm; 1—inch
max.
68-100 %
170
X
100
=
Press ENTER then ESC
LCD screen 7
th
)
14
Mar 2016
MSC-18K
th
)
Operation prompts
Encoder alignment
Set of Unit / Stroke
th
LCD screen 6
00
stroke
170 cm