5.0 Additional Copper Tests

5.1 Voltage
Purpose
MultiMeter is used to measure Voltage. The presence of excessive AC
voltage is often due to induction from the AC power grid. The presence of
any DC voltage is an indication of a resistive coupling (cross) to one or
more working pairs (with CO battery).
Test Interface
Procedure
1. Connect a Tip Ring and Ground cable from the
line to the Tip, Ring and Ground connector on
the top of the test set.
2. Under Copper select Multimeter.
3. Press Snapshot to automatically provide the AC
and DC voltage across each of the Tip, Ring,
and Ground pairs.
4.
Select Continuous to provide real time access
to pairs.
5.
Touch or use the up down arrow keys to cycle
through the pairs.
6.
Press AC Volts or DC Volts to Cycle through
the tests.
If Required Select Option to change the Termina-
tion between 100K and 1 Meg ohm, default is 100K.
June-2015
Technical Assistance: 1-844-GO-VIAVI;