3. INITIAL SETTINGS
3. Select the [Communication Port Monitor] from the [Tests] menu.
The communication port monitor window appears.
4. Select a port tab ([Serial Port1] to [Serial Port5]) to show the corresponding port.
5. Press the [Settings] button (
6. Select a NMEA format among Ver 1.5, Ver 2.0 and Ver 3.0.
Note: When the NMEA format is changed, the defaults settings are restored for
the items in the same window.
7. Select output data from [Depth], [Temperature] or [Hardness And Roughness].
You can select more than one datum.
8. Select a TLL output data from [TLL], [FURUNO-TLL] or [Off].
• [TLL]: Shows L/L data output
• [FURUNO-TLL]: Shows L/L, water temperature and fish size data output
• [Off]: No output of the longitude/latitude data.
Note: These output data require appropriate external data input.
9. Select a baud rate from 600, 4800 or 38400 bps at [Baud Rate], then click the [OK]
button to close the menu.
Note: Select [38400] bps when the [TLL Output] is set to [FURUNO-TLL]. [4800]
or [600] bps may slow the transmission of sentences.
10. Push the [OK] button to close the port setting menu.
11. Set the parameters for other port tabs referring to this procedure's steps 4 to 10.
12. Press the [Close] button to close the [Communication Port Monitor] window.
Communication port monitor
The serial signal monitor is available for each port.
• Serial Port 1: NMEA1 port on processor unit.
• Serial Port 2: NMEA2 port on processor unit.
• Serial Port 3: NMEA3 port on processor unit.
• Serial Port 4: NMEA4 port on processor unit.
• Network: Network (LAN) port on processor unit.
Select the port tab from the communication port monitor window, then press the [Up-
date] button to display the received data for selected port.