Errors During The Programming Procedure - Weco Power Pulse 400 Software Update Manual

Table of Contents

Advertisement

Cod.006.0001.1700
02/09/2016 v1.1
ENGLISH
2.3

ERRORS DURING THE PROGRAMMING PROCEDURE

16/18
Communication port not recognized.
- Disconnect the USB/RS232 adapter from the PC port, wait 30
seconds and then reconnect it.
- Make sure you have entered the correct number of the USB SERIAL
PORT in the VIA COM-PORT field.
The value entered in the PROG BAUDRATE field is too high.
- Set the value to 9600.
Data communication disturbance.
- Electromagnetic fields due to HF discharges or on-going welding
operations can cause interference on data communications. Program
the unit in an area well away from such sources of interference.
Communication cannot be established with the unit to be programmed.
- Make sure the unit is powered on.
- Check to ensure the cables between the PC and the unit are
connected correctly.