Troubleshooting
Blockage Related
Blockage Related
Black soot on outside of house
•
Confirm exhaust path is clean and clear (Zone 1 and 3)
- Adjust air/fuel ratio using trim adjustment dial
(See page 23 for trim adjustment instructions)
•
Ensure termination cap has at least 18" clearance to reduce
the effects of soot blow-back on home exterior (ie. siding)—if
not able, refer to page 10 for alternate installation options
Rumbling/whistling noise during operation
•
Confirm exhaust path is clean and clear (Zone 1 and 3)
- Adjust air/fuel ratio using trim adjustment dial (See page 18 for trim adjustment instructions)
Stove will not light
•
Confirm firebox is clean and clear (Zone 1)
- Igniter is getting hot (glows orange)
•
Inspect Stove body (Zone 2)
- Confirm fuel is in hopper, close lid securely
- Remove right side panel to access and confirm vacuum switch is clear and
connected at both ends
- Confirm all exhaust blower connections ........... secure
- Confirm the feed assembly and motor are clean and clear of debris
•
Confirm exhaust path is clean and clear (Zone 3)
30
PelPro Pellet Stove • 7083-801F • 04/21
Zone
1
Zone
3
Zone
2
pelprostoves.com
Troubleshooting
Blockage Related
Fire starts but goes out
•
Confirm firebox is clean and clear (Zone 1)
- Ensure fire pot holes are clear
•
Inspect Stove body (Zone 2)
- Confirm exhaust probe is connected
- Inspect and clean the exhaust outlet
•
Confirm exhaust path is clean and clear (Zone 3)
Starts and stops frequently in automatic mode
•
Determine if your room is experiencing varying temperatures due to repeated opening/closing of doors or
windows—correct if necessary
•
Examine Stove body (Zone 2)
- Inspect ambient probe and confirm that at least 2" is exposed outside of Stove body
Slow or smoky start-up and/or lazy flame
•
Confirm exhaust path is clean and clear (Zone 3)
•
Examine Stove body (Zone 2)
- Align igniter so it is properly placed and centered
- Review fuel quality (see Pellet Fuel information on page 13)
pelprostoves.com
PelPro Pellet Stove • 7083-801F • 04/21
Zone
1
Zone
3
Zone
2
31