Vent Termination Clearances; Placing Your Stove - Pelpro PP60 Owner's Manual

Hide thumbs Also See for PP60:
Table of Contents

Advertisement

Installing Your Stove

Vent Termination Clearances

Vent Termination Clearances
B
D.
A
Clearances
A
12"
Clearance above grade, veranda porch, deck or balcony (Including vegetation and mulch)
12"
Clearance beside or below any windows or doors that open
B
12"*
Clearance above any window or door that opens
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from
C
18"
the center line of the terminal
D
12"
Clearance to an outside corner wall
12",
F
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other Stove
48" no outside air kit
G
36"
Clearance to a mechanical air supply inlet
H
84"**
Clearance above a paved sidewalk or paved driveway located on public property
I
12"**
Clearance under a veranda, porch, deck or balcony
J
12"
Clearance above the roof
K
24"
Clearance from an adjacent wall including neighboring buildings
36" within a height of 15
Clearance to each side of center line extended above natural gas or propane meter / regulator assembly or
L
feet above the meter /
mechanical vent
regulator assembly
*Recommended to prevent condensation on windows and thermal breakage. **This is a recommended distance. For additional requirements check local codes.
NOTICE:
Do NOT terminate vent:
In any location that will allow flue gases or soot
from entering or staining the building
In any location which could create a nuisance or
hazard
In any enclosed or semi-enclosed area such as
a carport, garage, attic, crawl space, under a
sun deck or porch or narrow walkway
Closely fenced area, or any location that can
build up a concentration of fumes such as a
stairwell, covered breezeway, etc.
8
PelPro Pellet Stove • 7083-801F • 04/21
C
K
J
I
B
F
G
H
L
NOTICE:
Do NOT terminate below an air inlet.
It is recommended that at least 60" (1.52m) of
vertical pipe be installed when Stove is vented
directly through a wall—this will create a natural
draft, which will help prevent the possibility of
smoke or odor venting into the home during a
power outage
It will also keep exhaust from causing a nuisance
or hazard by exposing people or shrubs to high
temperatures
The safest and preferred venting method is to
extend the vent vertically through the roof or
above the roof
pelprostoves.com
Installing Your Stove

Placing Your Stove

Placing Your Stove
1
It is necessary to install EMBER PROTECTION; a Type I floor protector for this Stove.
The Floor protector must be non-combustible material, extending beneath Stove with a minimum of 6 inches
(152mm) in front of glass and 6 inches (152mm) to both sides of the fuel loading door. Open the door and
06/05/14
MCW
2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
06/19/13
MCW
measure 6 inches (152mm) from the side edge of the opening in the face of the Stove.
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
DATE
BY
The appliance will automatically maintain the desired comfort level and shut down when level has
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le
1
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha
** The appliance will run continuously until switched to OFF or COMFORT LEVEL mode.
L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou NIVEAU DE CONFORT.
El aparato funciona continuamente hasta que cambia al modo OFF o NIVEL DE CONFORT.
NOTE:
1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK
1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK
2. BACKGROUND: SILVER
3. COPY: BLACK
4. ADHESIVE: 3M #468 PERMANENT ACRYLIC
5. TEMPERATURE RATING: -50°F TO 350°F
75292
Notice: Be careful to protect the bottom of the Stove and floor surfaces when moving the Stove. Bottom edges
D
GROUPED LANGUAGES, REMOVED PHONE NUMBER
74013
of Stove are sharp and can scratch surfaces.
C
BACKGROUND AND COPY NOTE UPDATD
73351
Notice: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.
Hearth pad minimum requirements:
2
USA Hearth Pad Requirements
Inches
A
Sides
B
Back
C
Front
Canada Hearth Pad Requirements
Inches
A
Sides
B
Back
C
Front
Non-combustible floor protection extending beneath the flue pipe is required with horizontal venting or under the top vent adapter
with vertical installation.
*Non-combustible floor protection must extend 2 inches (51mm) beneath the flue pipe when installed horizontal venting or under
the top vent adapter with vertical installation. CANADA REQUIRED, USA RECOMMENDED.
pelprostoves.com
PelPro Pellet Stove • 7083-801F • 04/21
Parada
DRAWN BY:
SCALE:
MATERIAL:
1. Gire el dial de control en la posición OFF.
MCW
1:1
SEE NOTE
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
B
ADDED WWW.PELPROSTOVES.COM
SHEET:
PART NUMBER:
75290
2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
7083-167
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
1 OF 1
A
RELEASED
72901
REV
REVISIONS
2
*
The appliance will automatically maintain the desired comfort level and shut down when level has
3
been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le
niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha
1
logrado.
** The appliance will run continuously until switched to OFF or COMFORT LEVEL mode.
Remove / Supprimer / Quitar
L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou NIVEAU DE CONFORT.
El aparato funciona continuamente hasta que cambia al modo OFF o NIVEL DE CONFORT.
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03
06/05/14
MCW
OUTSIDE MATERIAL.
01/07/14
WPK
9/3/2013
WPK
2
mm
B*
2
51
2
51
A
A
6
152
mm
C
8
203
2
51
6
152
(3) PLACE DEC:
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pp60-b

Table of Contents