Installing Your Stove
Confirm required clearances to combustibles:
3
Vertical Installations (Interior Flue)
Straight back against wall
D
Back wall to pellet pipe
E
Side wall to Stove
Corner Installation
Straight back against wall
F
Walls to Stove
Horizontal Installations
Straight back against wall
G
Back wall to Stove
E
Side wall to Stove
10
PelPro Pellet Stove • 7083-801F • 04/21
3
D
G
Inches
mm
3
254
13
330
Inches
mm
3
76
Inches
mm
2
51
13
330
F
pelprostoves.com
Installing Your Stove

Venting Your Stove

Venting Your Stove
CAUTION!
Take appropriate precautions to locate utilities within the wall and avoid contact.
E
1
Mark and cut wall for venting penetration on exterior wall (if needed).
Install wall thimble (sold separately) per manufacturer requirements.
2
3
Install venting. (For additional installation options visit pelprostoves.com)
Use silicone to create an effective vapor barrier at the location where the chimney or other
4
component penetrates to the exterior of the structure.
Vertical - Interior, Preferred Installation
Firestop
F
Ceiling Support
6 in.
(152mm)
Min.
PART NAME
ITEM
4X R0.13
NOTE: In Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100 o F) CLASS "A" or
conforming to CAN/ULC-S629M, STANDARD FOR 650 o C FACTORY-BUILT CHIMNEYS.
Pro Tips
See venting manufacturer's required clearances to combustibles
For horizontal installations, the minimum clearance from exterior to termination cap is 6"—you
may want to increase to 18" clearance to minimize soot blow back on home exterior.
Install vent at clearances specified by the manufacturer
WARNING!
Do not terminate venting in any enclosed or semi-enclosed area
such as: a carport, garage, attic, crawl space, under a sun deck
or porch, narrow walkway or closely fenced area, or any location
that can build up a concentration of fumes such as a stairwell,
covered breezeway, etc.
pelprostoves.com
Exterior - Optional Installations
Rain Cap
Flashing
12 in. (305mm) Minimum
Wall Thimble
Follow pipe manufacture
listed clearance
6 in. (152 mm)
Minimum
Clean-out T
QTY
ITEM
-
PART NUMBER
-
----
-----
Non-combustible Hearth Pad
Non-combustible
Hearth Pad
11.75
PART NUMBER
PART NAME
QTY
CAUTION!
Ensure that your Stove venting terminates above
your Stove. The following may occur:
• Your Stove Stove will not draft properly
• Smoke may seep in your house
• Excessive sooting
PelPro Pellet Stove • 7083-801F • 04/21
Termination
Cap
6 in.
(152 mm)
Minimum
Wall Thimble
Horizontal
Termination Cap
6 in.
(152 mm)
Clean Out T
Minimum
11