Control Board
1. Turn the dial control to the off position. Unplug the
power to the unit.
2. Unplug the wires from the control board. The
connectors are locking connectors. Pinch the release
tab on each connector and gently tug and rock loose.
3. Pinch the 4 plastic pins from the rear of the unit
with needle nose pliers to release the control board
connectors.
4. Install new board following the steps in reverse.
Replacement kit: SRV7079-050
Feed Motor Assembly
1. Turn the dial control to the off position and unplug the appliance. Remove the right side panel
and feed motor cover plate in the rear of the appliance.
2. Remove the 4 screws and cover plate.
3. Remove remaining pellets in feed assembly.
4. Unplug feed motor from wire harness.
5. Remove silicone from around bushing end cap. Using Phillips head screwdriver remove 2
screws retaining the end cap to the feed tube.
6. From inside the hopper, lightly tap on the end cap alternating side to side to remove feed
assembly from feed tube.
7. Re-install new feed assembly in reverse order; ensuring that the top of the feed bushing
is in place and the bushing end cap is symmetrical in the feed tube chamber prior to final
tightening of the retaining screws. Silicone the end cap to the feed tube.
8. Plug the feed motor leads back in and restore power.
Replacement kit: SRV7077-014
28
PelPro Pellet Stove • 7083-801F • 04/21
A
RELEASED
REV
REVISIONS
Zone
Zone
1
1
Zone
Zone
2
2
Zone
Zone
3
3
pelprostoves.com

Troubleshooting

Troubleshooting
Troubleshooting your Stove
Visit
pelprostoves.com
or scan the code:

Power Related

Power Related
In the event of a power outage:
If using a generator, PelPro recommends a steady state
generator for best Stove performance.
This Stove needs 110v to run properly. This Stove has not
been tested for use with a third party battery backup.
Stove plugged in but no response
Unplug your Stove
Check your home's circuit breaker
Reset snap disc (located between drop tube and hopper
(Zone 2)
A
Visually inspect wires, blowers and power cord for breaks
or wear to find cause of possible short circuit (Zone 2)
Component (i.e. blower) fails to start or fails to turn off
Unplug your Stove
Check all connections and power plugs are secure
Visually inspect wires, blowers and power cord to find
cause of possible short circuit
pelprostoves.com
PelPro Pellet Stove • 7083-801F • 04/21
Pro Tip
Check passages to assure
they are clear of ash and
obstructions. Poor airflow
leads to poor performance of
your Stove.
A
Zone
1
Zone
3
Zone
2
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pp60-b

Table of Contents