Extreme Networks ExtremeSwitching VSP 7400 Series Hardware Installation Manual page 28

Table of Contents

Advertisement

Place the equipment in an area that accommodates the power consumption and component heat
dissipation specifications.
Be sure that your power supply meets the site DC power or AC power requirements of the network
equipment.
When you connect power to installed equipment, do not make this connection through an extension
cord or power strip.
If your switch includes more than one power supply, connect each power supply to a different,
independent power source.
If a power source fails, it will affect only the switch power supply to which it is connected. If all switch
power supplies are connected to a single power source, the entire switch is vulnerable to a power
source failure.
In regions that are susceptible to electrical storms, we recommend that you plug your system into a
surge suppressor.
For detailed power specifications for your equipment, see "Technical Specifications."
Requirements for Power Cords
Most ExtremeSwitching switches do not ship with power cords. Visit
product/powercords/
specific Extreme Networks equipment. The web page provides specifications for power cords in each
country so that you can purchase cords locally.
AC power cords must meet the requirements listed in
Switches and AC Power Supplies
UPS (Uninterruptible Power Supply) Requirements
A UPS (uninterruptible power supply) is a device that sits between a power supply (such as a wall
outlet) and a device (such as a switch) to prevent outages, sags, surges, and bad harmonics from
adversely affecting the performance of the device.
A UPS traditionally can perform the following functions:
Absorb relatively small power surges.
Smooth out noisy power sources.
Continue to provide power to equipment during line sags.
Provide power for a period of time after a blackout has occurred.
In addition, some UPS devices or UPS-plus-software combinations provide the following functions:
Automatically shut down equipment during long power outages.
Monitor and log power supply status.
Display the voltage (current draw) of the equipment.
Restart equipment after a long power outage.
Display the voltage currently on the line.
Provide alarms on certain error conditions.
Provide short-circuit protection.
VSP 7400 Series Switches: Hardware Installation Guide
for information on selecting and purchasing the correct power cords for use with
on page 74.
www.extremenetworks.com/
Power Cord Requirements for AC-Powered
Preparing to Install
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeswitching vsp7400-32cExtremeswitching vsp7400-32c-ac-fExtremeswitching vsp7400-32c-ac-rExtremeswitching vsp7400-48y-8cExtremeswitching vsp7400-48y-8c-ac-fExtremeswitching vsp7400-48y-8c-ac-r ... Show all

Table of Contents