Simrad EK80 Harbour Acceptance Test page 28

Wide band scientific echo sounder
Hide thumbs Also See for EK80:
Table of Contents

Advertisement

Simrad EK80 Harbour Acceptance Test
• All relevant external sensors are connected to the EK80. The sensors are turned
on and operate normally.
• The vessel is berthed.
Neither tools nor instruments are required.
Caution
You must never set the EK80 to "ping" unless the transducer is submerged in water.
The transducer may be damaged if it transmits in open air.
Procedure
1
Make sure that the EK80 units have been set up to operate with the supply voltage
you have available.
2
Make sure that the transducer cables are not installed close to power cables.
3
Turn all EK80 system units on.
4
Make sure that the power LED on the Wide Band Transceiver (WBT) is lit.
5
On the Processor Unit desktop, double-click the EK80 icon to start the program.
6
Open the
About
7
Make sure that the latest software version is installed.
8
Start normal operation.
9
Make sure that the EK80 user interface is fully operational.
a
Make sure that the EK80 visual presentation is shown with adequate quality.
If necessary, adjust the display and/or the relevant properties in the Processor
Unit operating system.
b
Make sure that the menu system offered by the EK80 is operational.
Make random selections, and make sure that the relevant sub-menus, functions
or dialog boxes are activated.
c
Make sure that the relevant views are operational.
Move the cursor to the views in the main EK80 presentation. Click inside one
of the views. Make sure that the view is activated, and that relevant changes
are made in any dynamic menus.
10 Select the icon on the top bar to open the
a
Verify that no error messages are presented during normal operation.
b
Close the dialog box by selecting
28
dialog box.
dialog box.
Messages
or [
] in its top right corner.
Close
X
401925/C

Advertisement

Table of Contents
loading

Table of Contents