Structure

Accessibility
BEFORE OPENING THE APPLIANCE, ALWAYS DISCONNECT IT FROM THE POWER SUPPLY. ALSO
SWITCH OFF THE MAIN WATER VALVE AT HOME TO AVOID FLOODING.
To access the internal parts of the appliance, proceed as described on instructions manual:
Take the drip tray lifting the front side first.
Lift locking spring placed under drip tray
Pull appliance from cabinet by pulling
At this point we have access to the water pressure reducer / filter / CO2 bottle side. We can
then apply some adjustments or procedures like:
Change filter (as described in instructions manual)
-
Change CO2 bottle or adjust level of carbonation by adjusting the CO2 bottle reducer
-
knob.
Reducing the water pressure, adjusting the manometer knob.
-
Start sanitizing procedure installing a sanitizing cartridge instead of filter (as described
-
in instructions manual)
Switch on/off the inlet manual valve to operate or change water tubes or 'wet'
-
components.