Electrolux PWE9038-M Service Manual page 23

Table of Contents

Advertisement

Alarms
Led indications
Led blinks slowly
Led is lit
Led is lit
Carbonated water
led blinks slowly
CO
bottle led on
2
Leds
- ambient water
- ice
blink
simultaneously
Ice forming bin blocked.
Turn unit on/off through main on/off switch on side of unit.
Leds
- ambient water
- cold water
- carbonated
water
Volumetric turbine malfunctioning. Dispense functions enabled but during
blink
dispense operation the 3 leds will blink.
simultaneously
Leds
- carbonated
water
- ambient water
- cold water
Main water tank fill time-out. Please check water supply to unit. Make sure filter
- ice
shut off valve to be open.
blink
To reset status turn unit on/off through main switch inside cabinet.
simultaneously
1.1.0 5.2007
Filter is about to exhaust. 2900 liters have been dispensed.
Please change filter as described in the following chapters.
Filter is about to exhaust. 2980 liters have been dispensed. Please
change filter as described in the following chapters.
All dispense buttons disabled.
3000 liters have been reached.
Please change filter as described in the following chapters.
Carbonated water is disabled.
Time-out protection on carbonation pump activated.
To reset status please turn unit off/on on touch control panel.
Carbonated water is disabled.
CO
bottle is empty.
2
Replace CO
bottle to restore Carbonated water dispensing.
2
Please change CO
bottle as described in the following chapters.
2
23/40