Avaya one-X 1603SW Administrator's Manual page 80

One-x deskphone value edition sip for ip deskphones
Hide thumbs Also See for one-X 1603SW:
Table of Contents

Advertisement

Administering Telephone Options
Table 11: 1603SW-I SIP IP Deskphones Customizeable System Parameters (continued)
Parameter Name
PHY2STAT
PHY2VLAN
PROCPSWD
PROCSTAT
RDS_INITIAL_RETRY_
ATTEMPTS
RDS_INITIAL_RETRY_
TIME
RECOVERYREGISTER
WAIT
REGISTERWAIT
RTCPCONT
80 Avaya 1603SW-I SIP Deskphones Administrator Guide
Default
Description and Value Range
Value
1
Secondary Ethernet interface setting
(0=Secondary Ethernet interface off/disabled,
1=auto-negotiate, 2=10Mbps half-duplex, 3=10Mbps
full-duplex, 4=100Mbps half-duplex, 5=100Mbps
full-duplex), and, for post-Release S1.0 use,
6=1000Mbps full-duplex (if supported by the hardware).
Speed and duplex issues are summarized and the best
practice is provided in the Avaya Application Solutions: IP
Telephony Deployment Guide, Document Number
555-245-600 Issue 6, January 2008 on page 290. This
document is available from the Avaya support website.
0
VLAN identifier used by frames received on or forwarded
to the secondary Ethernet interface. Set this parameter
only when VLAN separation is "1" (enabled). Value is 1-4
ASCII numeric digits from "0" to "4094." Null is not a valid
value, nor can the value contain spaces.
27238
Text string containing the local (dialpad) procedure
password (Null or 1-7 ASCII digits). If set, password must
be entered immediately after accessing the craft
interface, either during initialization or when Mute is
pressed to access a craft procedure. Intended to facilitate
restricted access to local procedures even when
command sequences are known. Password is viewable,
not hidden.
0
Controls access to Craft local (dialpad) administrative
procedures. Values are:
0 = Full access to craft local procedures
1 = restricted access to craft local procedures
15
Indicates how many times the PPM adaptor should try to
download from PPM before giving up on connecting to
the PPM server. Values are: 1-30.
2
Remote Data Source initial retry time in seconds;
indicates the initial delay for a retry to connect to the PPM
server. Valid range is 2-60 (seconds).
60
Reactive monitoring interval in seconds for Failover. Valid
values are: 10 - 36000
900
Number of seconds for next re-registration to SIP server.
The default value for software Release 2.4+ was
originally set to 300 to accommodate UDP, however,
TCP/TLS is the recommended arrangement and is the
most typical configuration; the default was changed from
300 to 900 seconds for software Release 2.5+. UDP
arrangements can be handled by setting the value of the
parameter to a lower value in the settings file. Range in
seconds: 30 to 86400
1
Enables/disables the RTCP in parallel to RTP audio
streams. Values are 0=RTCP disabled, 1=RTCP
enabled.