1 | General information
1.3.3
Additional information symbols
NOTE
Useful information and notes
Information that is important in relation to a specific topic or objective but is not related to safety.
1.3.4
Layout of action steps
↻ Pre-requisite for the action
1. Carry out first action step
2. Next action step
ð Intermediate outcome of the action step
ð Final outcome
1.4

Identification

You will find the name plate with the following data for service and other require-
ments specific to installation on the right side panel of the product:
– Product name
– Part no.
– Serial no.
– Date of manufacture
– Technical data
– Disposal information
– Certification marking, CE marking.
1.5

Warnings on the device

A warning sticker is affixed to the device. Read the warnings carefully.
Do not remove the sticker. If the sticker is missing or is illegible, please contact a
KACO representative or distributor.
– Article number: 3013153
1.6

Target group

All activities described in the document may only be carried out by specially trained personnel with the follow-
ing qualifications:
– Knowledge about how an inverter functions and operates.
– Training in the handling of hazards and risks during the installation and operation of electrical units and
plants.
Page 6
Manual
KACO blueplanet 125 TL3 M1 WM OD IIP0
Part number
1001623
Serial number 125TL01654321
KACO new energy
Carl-Zeiss-Straße 1
74172 Neckarsulm
Made in Germany
Vmax PV / lsc PV (max) / Inom PV
1500 V / 300 A / 160 A
Input
V-MPP at Pnom / V- range
875V - 1300V / 875V - 1450V
600 V (3P+PE)
Nominal voltage
Output
Voltage range continuous operation
480 V - 760 V (Ph-Ph)
Current (maximum continuous)
3 x 132,3 A
Frequency range
45 Hz - 65 Hz
Snom at 600 V Unom
125 000 VA
137 500 VA
Smax at 600 V Unom
Output
Power
Reactive power
cos phi
Environ-
Temperature range
- 25...+60°C / -13...+140 °F
ment
Protection class / Ingress protection
I / IP66 / NEMA 4X
No galvanic separation / Ungrounded Arrays Only
M
ax. Backfeed Current
Grid Support Interactive Inverter
ARC fault circuit protection
Interface protection according to country specific requirements, details see manual
Conf. to UL 1741 & UL 62109-1
Cert. to CSA C22.2 No. 107.1 &
CAN/CSA Std. C22.2 No. 62019-1
CAN/CSA Std. C22.2 No. 62109-2
Fig. 1: Name plate
Fig. 2: Warning sticker
KACO blueplanet 110 TL3 KACO blueplanet 125 TL3 US
Year Q4 / 18
0,3-1 ind/cap
0 A
none