3.2.3
Interfaces
You can configure the interfaces and the web server in the Settings menu. The device has the following inter-
faces for communication and remote monitoring.
Ethernet interface
The device features two switched Ethernet ports to enable the user to, for example, connect several devices in
series if the user prefers a linear topology.
RS485-Interface
The device features two RS485-Interfaces. One RS485-Interface is earmarked for communication with a string-
combiner-box. This can be controlled using the Modbus RTU protocol. Data loggers that cannot be connected
via Ethernet can be connected to the other RS485-Interface. The Sunspec and KACO protocol are supported in
this case.
USB interface
The device's USB connection is a type A socket. It is located on the communication circuit board. The USB con-
nection is specified to draw 500 mA of power.
Use the USB interface to read out stored operating data, load software updates or device configurations using a
FAT32-formatted USB stick.
It is possible to establish a connection to the webserver integrated into the device by connecting a USB-WiFi
stick. In addition to starting up the device, the web interface can be used for service information purposes,
software updates and for carrying out extensive configuration.
"Inverter Off" input / DRM0
In addition to the safety functions, the internal interface switches can also be actuated via the "Inverter Off" in-
put.
The Powador-protect or a protective device from another manufacturer can be used for this purpose.
If a Powador-protect is used as the central interface protection, the fail-safe disconnection of suitable KACO in-
verters from the public grid can be carried out by the internal interface switches instead of separate interface
switches. This requires the inverters in the photovoltaic system to be connected to the Powador-protect.
Information on installation and use can be found in this manual, in the Powador protect manual and in the in-
structions for use of the Powador protect on the KACO web site.
At the "Inverter Off" input, instead of the Powador-protect an interface protection device from another sup-
plier can also be connected to actuate the internal interface switches.
3.3

Plant layout

PV generator
String combiner with DC isolator switch
Fig. 6: Circuit diagram with a short or long supply cable to the inverter
KACO blueplanet 110 TL3 KACO blueplanet 125 TL3 US
Device description | 3
PV generator
RS485
*
String combiner with DC isolator switch
Inverter
with circuit-breaker
AC
Inverter
with circuit-breaker
Switch box