Freeze Protection Of Branch Box Or Indoor Unit - Mitsubishi Electric PUMY-P250YBM Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P250YBM:
Table of Contents

Advertisement

Check code

Freeze protection of branch box or indoor unit

1503
(P6)
Abnormal points and detection methods
The purpose of the check code is to prevent indoor unit from freezing or
dew condensation which is caused when a refrigerant keeps flowing into
the unit in STOP.
When all of the following conditions have been satisfied:
1. The compressor is operating in COOL mode.
2. 15 minutes have passed after the startup of the compressor, or the
change in the number of operating indoor units is made (including a
change by turning thermo-ON/OFF).
3. After the condition 2 above is satisfied, the thermistor of indoor unit
in STOP detects TH22j [ −5
●Diagnosis of defects
Make sure to turn the power OFF before connecting/disconnecting any connectors, or replacing boards.
Check the port which the piping and
wiring between the indoor unit and
branch box is connected.
Is the piping and wiring connected
to the same port?
Check the port which the LEV wiring
of branch box is connected.
Is the wiring connected to the same
port as the corresponding branch
box?
Check the LEV wiring of indoor unit
that is not connected via branch box
is connected properly.
Disconnect the LEV wiring of branch box
or indoor unit to check the resistance.
Is the resistance detected?
OCH760
[23°F] for 5 consecutive minutes.
Diagnosis
Yes
Yes
Yes
Yes
Causes and checkpoints
Wrong piping connection between indoor unit and
branch box
Miswiring between indoor unit and branch box
Miswiring of LEV in branch box or indoor unit
Malfunction of LEV in branch box or indoor unit
Connect the piping and wiring to the same
No
port.
Connect the LEV wiring to the intended
No
port properly.
No
Connect the LEV wiring properly.
No
Replace the LEV assy in branch box or
the LEV of indoor unit that is not connected
via branch box.
54
Remedy
Replace the LEV coil.