2. Indoor Unit Installation

2-1. Fixing of Installation Plate
• Find a structural material (such as a stud) in the wall and fix installation plate (1) horizon-
tally by tightening the fixing screws (2) firmly.
• To prevent installation plate (1) from vibrating, be sure to install the fixing screws in the
holes indicated in the illustration. For added support, fixing screws may also be installed
in other holes.
• When the knockout is removed, apply vinyl tape to the knockout edges to prevent damag-
ing the wires.
• When bolts recessed in the concrete wall are to be utilized, secure installation plate (1)
using 11 × 20 · 11 × 26 oval hole (450 mm pitch).
• If the recessed bolt is too long, change it for a shorter one available in the market.
2-2. Wall Hole Drilling
1) Determine the wall hole position.
2) Drill a ø75 mm hole. The outdoor side should be 5 to
7 mm lower than the indoor side.
3) Insert wall hole sleeve (C).
Installation plate (1)
Level
157 mm
or more
Wall
Fixing screw (2)
Wall
ø75 mm
Ceiling
95 mm or more/
151 mm or more for left/left rear
piping (using spacer)
187 mm
or more
100 mm
Insert
Align the
the
scale with
scale. *
the line. *
* Same for left hole.
2-3. Connecting Wires for the Indoor Unit
You can connect indoor/outdoor lead wire without removing the front panel.
1) Open the front panel.
2) Remove wire fixture.
3) Pass indoor/outdoor unit connecting wire (A) from the back of the indoor unit and process
the end of the wire.
4) Loosen terminal screw, and connect first the earth wire, then indoor/outdoor unit con-
necting wire (A) to the terminal block. Be careful not to make mis-wiring. Fix the wire to
the terminal block securely so that no part of its core is appeared, and no external force
is conveyed to the connecting section of the terminal block.
5) Firmly tighten the terminal screws to prevent them from loosening. After tightening, pull
the wires lightly to confirm that they do not move.
6) Secure indoor/outdoor unit connecting wire (A) and the earth wire with the wire fixture.
Never fail to hook the claw of the wire fixture. Attach the wire fixture securely.
5-7 mm
Outdoor
side
15 mm
35 mm
60 mm
or more
Earth wire
Others
Wall
Center of
• For future servicing, give extra length to
ø75 mm hole
the connecting wires.
• Make earth wire longer than others as
picture.
• Do not fold the excess wire, or cram it into
small space. Take caution not to damage
the wires.
• Be sure to attach each screw to its corre-
spondent terminal when securing the cord
and/or the wire to the terminal block.
Note: Do not place the wires between the
indoor unit and the installation plate (1).
Damaged wire could cause heat genera-
tion or fire.
Terminal block
15 mm
35 mm
Earth wire
(green/yellow)
Indoor/outdoor
unit connecting
wire (A)
Claw
Wire fixture
Fixing screw
Indoor/outdoor unit
connecting wire (A)
Indoor terminal block
S1 S2 S3
S1 S2 S3
Outdoor terminal block