82Z30000.book 11 ページ 2010年6月25日 金曜日 午後5時50分
CONNECTING ROD BIG END I.D.
Set the connecting rod lower to the connecting rod
upper.
Apply engine oil to the connecting rod bolt threads and
seating surface.
Tighten the connecting rod bolts to the specified torque.
TORQUE: 14 N·m (1.4 kgf·m, 10 lbf·ft)
Measure the connecting rod big end I.D.
EG3600CX/EG4000CX:
Except EG3600CX/EG4000CX:
If the measurement is more than the service limit,
replace the connecting rod (page 14-6).
CONNECTING ROD BIG END SIDE
CLEARANCE
Measure the clearance between the connecting rod big
end and crankshaft using a feeler gauge.
STANDARD:
SERVICE LIMIT:
If the measurement is more than the service limit,
replace the connecting rod (page 14-6) and recheck the
clearance.
If the clearance is still more than the service limit with
the new connecting rod, replace the crankshaft (page
14-4).
CONNECTING ROD BIG END OIL
CLEARANCE
Clean all oil from the crank pin and connecting rod big
end surface.
Place a piece of plastigauge on the crank pin, install the
connecting rod upper and the connecting rod lower.
Apply engine oil to the connecting rod bolt threads and
seating surface.
Tighten the connecting rod bolts to the specified torque.
TORQUE: 14 N·m (1.4 kgf·m, 10 lbf·ft)
Do not rotate the crankshaft while the plastigauge is in
place.
STANDARD:
33.025 – 33.039 mm
(1.3002 – 1.3007 in)
SERVICE LIMIT:
33.07 mm (1.302 in)
STANDARD:
36.025 – 36.039 mm
(1.4183 – 1.4189 in)
SERVICE LIMIT:
36.07 mm (1.420 in)
0.1 – 0.4 mm (0.004 – 0.016 in)
1.0 mm (0.04 in)
CYLINDER BLOCK
PLASTIGAUGE
14-11