82Z30000.book 16 ページ 2010年6月25日 金曜日 午後5時50分
GENERATOR/CHARGING SYSTEM
CONTINUITY INSPECTION
SINGLE MAIN WINDING TYPE:
Remove the generator end cover (page 7-15).
Remove the nuts and disconnect the main winding
terminal
Measure the resistance between the stator side
terminals according to the table below.
EG4000 (RH, KH, MH type)
EG3600 (UH type)
EG4000 (RHH type)
EG5000 (RH, KH, MH type)
EG4500 (UH, RGH type)
EG5000 (RHH type)
EG5000 (SH, SKH type)
EG6500 (RH, KH, MH type)
EG5500 (UH, RGH type)
EG6500 (RHH type)
EG6500 (SH, SKH type)
If the specified resistance is zero or infinity, replace the
stator.
7-16
and main winding terminal
.
Main winding terminal
(Brown) and
(White)
(Brown) and
(White)
Main winding terminal
(Brown) and
(White)
(Brown) and
(White)
(Brown) and
(White)
Main winding terminal
(Brown) and
(White)
(Brown) and
(White)
(Brown) and
(White)
Resistance (Ω)
(at 20 °C/68 °F)
1.3
1.4
Resistance (Ω)
(at 20 °C/68 °F)
0.8
0.9
0.7
Resistance (Ω)
(at 20 °C/68 °F)
0.6
0.7
0.5